Operate LIFT KNOB
(1)
to verify that STOPPER
(2)
opens and
closes.
Note:
If STOPPER
(2)
does not open and close properly, refer
to the “troubleshooting section” of these instructions.
CHECK OPERATION OF POP-UP
8
3
ATTACH CABLE CONNECTOR
7
2
1
1-1/4” O.D.
2
1
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer
must purchase additional parts separately.
Important: If FLEXIBLE SUPPLIES
(1, 2)
are to long,
loop to avoid kinking.
Connect 1-1/4" O.D. tailpiece on POP-UP DRAIN to
waste outlet.
Connect FLEXIBLE SUPPLIES
(1, 2)
directly to wall supplies.
Connection on fitting supplies is 3/8" compression. Connect
FLEXIBLE SUPPLY
(1)
(Marked with a Red Band) to the Left wall supppy and
FLEXIBLE SUPPLY
(2)
(Marked with a Blue Band) to Right wall supply.
9
Connect the VALVE HOSES
(3, 3a)
to SPOUT TEE
(4)
.
Use adjustable wrench to tighten connections.
Do not over tighten.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
Fig.
A.
Fig.
B.
WASTE
OUTLET
HOT
COLD
1
3
3a
4
2
Blue Stripe
(C0LD)
Red Stripe (HOT)
Thread CABLE CONNECTOR
(1)
clockwise
onto CABLE ATTACHMENT POINT
(2)
and
hand tighten.
Fig.
A.
Your new POP-UP DRAIN installation is
now complete.
Fig.
B.
Note:
Tailpeice on pop-up drain is 1-1/4” O.D.
Fig.
B.
M965622 Rev. 1.2 (12/17)