APPROX. 20
"
COLD
HOT
3/8" COMPRESSION
RED
BAND
BLUE
BAND
MAKE WATER SUPPLY
4
5
Connect FLEXIBLE SUPPLIES
(1, 2)
directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY
(1)
to Hot (Marked with a Red Band) and right supply
to COLD
(2)
wall supply.
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES
(1, 2)
are to long, loop as
illustrated to avoid kinking.
M965263 REV. 1.9 (8/17)
TEST INSTALLED FITTING and CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, adjust POP-UP ROD
(6)
.
Release POP-UP KNOB
(4)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
With HANDLE
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate HANDLE
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
.
2
3
INSTALL POP-UP DRAIN
ASSEMBLE PIVOT ROD
TO POP-UP DRAIN
Install FOAM GASKET
(4)
onto BODY
(2)
.
Install FLANGE
(1)
onto BODY
(2)
.
Tighten LOCK NUT
(3)
with channel locks.
Do not over tighten.
2
5
2
“P” TRAP
AERATOR
KEY
WASTE
OUTLET
3
6
4
1
1
2
Unthread PIVOT NUT
(1)
from drain body.
Remove CLIP
(2)
from pivot rod
(3)
.
Insert PIVOT ROD
(3)
through PIVOT NUT
(1)
as shown,
making sure the SEALS
(4)
are in place.
Thread PIVOT NUT
(1)
onto drain body.
Insert PIVOT ROD
(3)
through second or third hole in
EXTENSION
(5)
, installing CLIP
(2)
as shown, to keep
EXTENSION
(5)
in place.
Insert POP-UP ROD
(6)
through faucet body and through
EXTENSION
(5)
. Tighten EXTENSION NUT
(7)
to secure it.
ON
COLD
HOT
OFF
2
4
1
3
3
1
2
5
6
7
4