INSTALL TOILET

a.  Position toilet squarely to wall and, with a rocking motion,
     press bowl down fully on wax ring and flange. Alternately
     tighten nuts until toilet is firmly seated on floor.

CAUTION: 

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b.  Install caps on washers.  (If necessary, cut bolt height to
     size before installing caps.)  
c.  Smooth off the bead of sealant around base. Remove
     excess sealant.

!

INSTALL TOILET SEAT 

Install toilet seat in accordance with manufacturer's directions.

If bowl fails to siphon, an 
adjustment may be required with 
the lift chain. Simply remove the 
bead chain from the retainment 
clip (see Fig. 9a) and take up 
slack on the chain, and reinsert 
on lift rod.  Make sure the chain 
is not too taut.

Before continuing, determine the type of water supply connection you have from 
the chart below and use the appropriate assembly parts required to properly 
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.

CAUTION: DO NOT USE 
CONE WASHER WITH 
PLASTIC SUPPLY LINE.

These parts must be used as 
illustrated to insure water-tight 
connection. Use of existing 
coupling nut may result in 
water leakage. Water supply 
tube or pipe must extend at 
least 1/2" inside threaded 
shank of valve (does not 
apply to flanged tubing).

Use existing 
coupling nut 
and washer.

Use existing spiral cone 
washer. Fluidmaster cone 
washer may not seal 
completely on spiral type 
supply line.

Captive cone 
washers already 
included. No 
additional 
washers needed.

CAUTION: Overtightening of 
LOCK NUT or COUPLING 
NUT could result in breakage 
and potential flooding.

METAL/COPPER

FLARED TUBING

METAL FLANGED

TUBING

METAL SPIRAL

TUBING

VINYL/BRAIDED

CONNECTOR

LOCK NUT

LOCK NUT

LOCK NUT

LOCK NUT

COUPLING
NUT

COUPLING
NUT

EXISTING
COUPLING
NUT

COUPLING
NUT

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

CONE
WASHER

EXISTING
CONE
WASHER

EXISTING
WASHER

With correct washers in place (see Step 8a), 
tighten COUPLING NUT 1/4 turn beyond 
hand tight. 

DO NOT OVERTIGHTEN.

BOLTS

BOLT CAP

CLOSET FLANGE

Adjust water level to level 
indicated on tank by adjusting 
float cup. See Step 10.

CLOSET BOLT

NUT

WASHER

ADJUSTMENTS: 
Turn supply on.

a.

b.

6

7

8a

8b

9

10

Turn on water supply. 
Submerge the FLOAT 
CUP under the water for 
30 seconds. Adjust the 
water to desired level by 
turning WATER LEVEL 
ADJUSTMENT ROD 
and moving FLOAT 
CUP up or down.

TANK
LEVER

REFILL
TUBE

WATER LEVEL 

ADJUSTMENT 

ROD

TOP

ARM

NIPPLE

Diagram 1

PARTS FOR WATER
CONNECTION
(SEE STEP 8)

CONE WASHER

THREADED
SHANK

SHANK
WASHER

COUPLING NUT
(HAND TIGHT ONLY)

FLOAT

CUP

CRITICAL LEVEL

MARK ("C.L.")

MUST BE

1" ABOVE

OVERFLOW PIPE

LOCK NUT

Fig. 9a

VALVE

BODY

FILL 

VALVE

ADJUSTABLE
HEIGHT

Содержание Elongated One-Piece Toilet 2003

Страница 1: ...4 29 3 4 756mm 8 203mm 1 3 4 44mm 1 1 4 32mm 15 381mm 13 1 2 343mm 10 3 4 273mm 28 1 8 714mm 16 3 4 425mm 17 3 4 451mm FINISHED WALL 18 1 2 470mm C L OF SEAT POST HOLES 5 1 2 140mm CENTERS 12 305mm 1 2 13mm 10 3 4 273mm 4 1 2 114mm SUPPLY AS REQ D FINISHED FLOOR 7 178mm 4 102mm CLOSET BOLT NUT TAPERED WASHER FLANGE Recommended fitting type for back to back installations Depending upon your plumbin...

Страница 2: ... of valve does not apply to flanged tubing Use existing coupling nut and washer Use existing spiral cone washer Fluidmaster cone washer may not seal completely on spiral type supply line Captive cone washers already included No additional washers needed CAUTION Overtightening of LOCK NUT or COUPLING NUT could result in breakage and potential flooding METAL COPPER FLARED TUBING METAL FLANGED TUBING...

Страница 3: ...ster will be replaced without charge Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products Fluidmaster shall not be responsible or liable for any damages caused by products used with Fluidmaster valves that were not manufactured by Fluidmaster Inc See next page for Champion 4 Ten Year Worry Free Limited Warranty 30800 Rancho Viejo Road San Juan Capistrano CA 92675 ...

Страница 4: ...se accident or other damage if it was not installed in accordance with American Standard s instructions or if it has been modified in a manner inconsistent with the product as shipped by American Standard This warranty DOES NOT COVER any damage caused by the use of in tank cleaners American Standard s option to repair or exchange the product under this warranty does not cover any labor or other co...

Отзывы: