M 9 6 8 9 8 6 Rev. 1. 3
CHECK CONNECTIONS FOR LEAKS.
Move HANDLE down into "off" position.
Turn on water supplies and check connections for leaks
.
Operate HANDLE
(2)
up and down, left and right to flush
water lines thoroughly.
Operate HAND SPRAY and check connections for leaks.
CHECK CONNECTIONS
FOR LEAKS
5
SERVICE
6
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
1
2
3
4
5
6
8
7
7
If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.
FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW CONTROL DEVICE,
unthread SPRAY AND HOSE ASSEMBLY and rinse clean FLOW CONTROL DEVICE.
Remove INDEX BUTTON
(1)
, loosen HANDLE SCREW
(2)
and remove HANDLE
(3)
.
Unthread the ESCUTCHEON CAP
(4)
. Unthread three MOUNTING SCREWS
(5)
.
Lift CARTRIDGE
(6)
off MANIFOLD
(7)
and remove CARTRIDGE SEALS
(8)
.
Place SEALS
(8)
into CARTRIDGE PORTS
(6A)
.
Replace ESCUTCHEON CAP
(4)
, HANDLE
(3)
, tighten HANDLE
SCREW
(1)
and install INDEX BUTTON
(2)
.
Clean MANIFOLD
(7)
, CARTRIDGE
(6)
ports and SEALS
(8)
.
Place CARTRIDGE
(6)
onto MANIFOLD
(7)
and tighten MOUNTING
SCREWS
(5)
alternately.
By restricting handle rotation and limiting the amount of hot water allowed
to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental
scalding. To set the maximum hot water temperature of your faucets, all you
need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE BUTTON
(1)
and loosen SET SCREW
(2)
. Pull
HANDLE
(3)
off valve stem. Pull off CAP
(4)
. Use a flat blade
screwdriver or your fingers to pull up and rotate red HOT LIMIT
SAFETY STOP
(5)
. Follow
Step "A" or "B"
to adjust min./max.
discharge temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
Replace ESCUTCHEON CAP
(4)
, HANDLE
(3)
, tighten
HANDLE SCREW
(1)
and install INDEX BUTTON
(2)
.
HOT LIMIT SAFETY STOP ADJUSTMENT
6
PRY RED RING FORWARD
AND ROTATE COUNTER-
CLOCKWISE ONE CLICK
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
"A"
"A"
"B"
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING NUMBERS
0
1
2
3
4
5
6
5
6A
CARE:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
FLOW CONTROL
DEVISE
SPRAY AND HOSE
ASSEMBLY