American Standard Ceramix 2000.10X Скачать руководство пользователя страница 5

M968760 Rev. 1.3   

Speed Connect™ Drain

Troubleshooting Guide

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled

as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

CABLE ADJUSTMENT PROCEDURE

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:
     •

 Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.

 

                                                                          

Fig.

 

B.

REMOVE
CAM

Fig.

 

E.

Fig.

 

F.

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. 

Fig.

 

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. 

Fig.

 

B, C.

 

Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig.

 

C.

Re-attach the Cable to the Drain Body Connection 

(2)

 by threading the Cable Connector 

(1)

 clockwise onto the

Drain Body Connection 

(2)

 and hand-tighten. 

Fig.

 

A.

STOPPER REMOVAL PROCEDURE

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE
CAM CAP

Fig.

 

C.

STOPPER

1

DOWN

5

Fig.

 

A.

Содержание Ceramix 2000.10X

Страница 1: ...ING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against mounting hole Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Fig B Adjust Faucet so that it is centered Tighten MOUNTING NUT 6 to complete faucet mounting Fig B Fig A Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American...

Страница 2: ...P 3 2 2 3 3 1 1 Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel Locks INSTALL DRAIN FROM BELOW FIXTURE 5 From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly 4 Fig A...

Страница 3: ... properly then refer to the troubleshooting section of these instructions M968760 Rev 1 3 1 APPROX 20 2 COLD HOT 3 8 COMPRESSION RED BAND BLUE BAND Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If a...

Страница 4: ...on hot or cold To clean inlets first turn off water supply then 3 ADJUSTMENT WHEN WATER IS TOO HOT ADJUSTMENT WHEN WATER IS TOO COLD PRY RED RING FORWARD AND ROTATE COUNTER CLOCKWISE ONE CLICK PRY RED RING FORWARD AND ROTATE CLOCKWISE POINTER ON HOT LIMIT STOP A B B RED RING HOT LIMIT SAFETY STOP A 0 1 2 3 4 5 6 By restricting handle rotation and limiting the amount of hot water allowed to mix wit...

Страница 5: ...ollow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B REMOVE CAM Fig E Fig F Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain...

Страница 6: ...k at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Ca...

Отзывы: