CHECK OPERATION OF POP-UP

8

MAKE WATER SUPPLY AND WASTE CONNECTIONS

9

Thread CABLE CONNECTOR 

(1) 

clockwise

onto DRAIN BODY CONNECTION 

(2)

 and

hand tighten. 

Fig.

 

A.

Your new POP-UP DRAIN installation is
now complete. 

Fig.

 

B.

Note: 

Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

 

B.

Fig.

 

A.

ATTACH CABLE CONNECTOR

7

2

1

Fig.

 

B.

1-1/4” O.D.

3

2

1

Operate LIFT KNOB 

(1)

 to verify that STOPPER 

(2) 

opens and

closes.

Note: 

If STOPPER 

(2)

 does not open and close properly then

refer to the “troubleshooting section” of these instructions.

M968760 Rev. 1.3   

1

APPROX. 20

"

2

COLD

HOT

3/8" COMPRESSION

RED
BAND

BLUE
BAND

Connect FLEXIBLE SUPPLIES 

(1, 2)

 directly to wall supplies.

Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY 

(1)

 to Hot (Marked with a Red Band) and right supply

to COLD 

(2)

 wall supply.

Faucet supplies are 20" long from faucet base.

Note: If additional supply length is required, installer must
purchase additional parts separately.

Important: If SUPPLY HOSES 

(1, 2)

 are to long, loop as

illustrated to avoid kinking.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

Содержание Ceramix 2000.10X

Страница 1: ...ING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against mounting hole Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Fig B Adjust Faucet so that it is centered Tighten MOUNTING NUT 6 to complete faucet mounting Fig B Fig A Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American...

Страница 2: ...P 3 2 2 3 3 1 1 Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel Locks INSTALL DRAIN FROM BELOW FIXTURE 5 From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly 4 Fig A...

Страница 3: ... properly then refer to the troubleshooting section of these instructions M968760 Rev 1 3 1 APPROX 20 2 COLD HOT 3 8 COMPRESSION RED BAND BLUE BAND Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If a...

Страница 4: ...on hot or cold To clean inlets first turn off water supply then 3 ADJUSTMENT WHEN WATER IS TOO HOT ADJUSTMENT WHEN WATER IS TOO COLD PRY RED RING FORWARD AND ROTATE COUNTER CLOCKWISE ONE CLICK PRY RED RING FORWARD AND ROTATE CLOCKWISE POINTER ON HOT LIMIT STOP A B B RED RING HOT LIMIT SAFETY STOP A 0 1 2 3 4 5 6 By restricting handle rotation and limiting the amount of hot water allowed to mix wit...

Страница 5: ...ollow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B REMOVE CAM Fig E Fig F Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain...

Страница 6: ...k at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Ca...

Отзывы: