American Standard Bath/Shower Trim Kit T028.50X Скачать руководство пользователя страница 3

M 9 6 8 8 3 4

4

Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem.

Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON.

Remove COVER by pulling straight out.

Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve.

TO GAIN ACCESS TO VALVE FOR SERVICING

Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.

Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).

Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.

Turn on water supply and see above for installing TRIM and HANDLE.

VALVE LEAKS WHEN SHUT OFF

BACK TO BACK INSTALLATION

BACK TO BACK INSTALLATION

ROTATE 180

˚

Remove PRESSURE BALANCE UNIT (5).

Remove CAPS (7) and clean valve thoroughly.

Examine balancing unit and check condition of O-ring on end of piston.  Piston should move back and forth.  Order Repair
Part M952100-0070A if balancing unit is defective.

Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.

Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.

Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.

Reassemble FIXATION RING (4) and CARTRIDGE (1).

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

1

2

9

5

5

7

8

6

4

3

INLETS

LARGE OUTLET

5

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.

Содержание Bath/Shower Trim Kit T028.50X

Страница 1: ...T 5 7 8 INLETS 1 2 NPT OUTLETS 1 2 NPT OUTLETS 1 2 NPT 3 3 8 3 3 8 3 3 8 THREADED INLETS Required Tools Flat Blade Screwdriver Adjustable Wrench Channel Locks Plumbers Putty or Caulking Phillips Screwdriver FINISHED WALL 4 BOTTOM OF TUB 74 FOR HEAD CLEARANCE 5 1 8 REF 7 7 8 REF 18 OPTIONAL 5 REF 1 2 NPT 1 5 8 to 3 1 4 1 2 NPT 7 1 8 OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65 AND 80 TOP OF TUB RI...

Страница 2: ...tate counterclockwise one number to limit hot water temperature Use ARROW 3 on CARTRIDGE 4 and NUMBERS 5 on HOT LIMIT STOP 1 for indication 1 5 1 5 4 4 3 3 2 2 1 2 3 4 Find correct position of HANDLE 1 and push HANDLE 1 onto VALVE STEM 4 Install HANDLE SCREW 2 and push in INDEX CAP 3 Check proper operation of HANDLE 1 Turn on water supply on and test installed fitting Operate valve and diverter sp...

Страница 3: ...CK TO BACK INSTALLATION ROTATE 180 Remove PRESSURE BALANCE UNIT 5 Remove CAPS 7 and clean valve thoroughly Examine balancing unit and check condition of O ring on end of piston Piston should move back and forth Order Repair Part M952100 0070A if balancing unit is defective Replace CAPS 7 and install PRESSURE BALANCE UNIT 5 Make sure inlets line up with two holes in bottom of casting Top flange sho...

Страница 4: ...2 1902 Weekdays 8 00 a m to 8 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2004 M909732 YYY0A SPOUT ESCUTCHEON M950225 YYY0A DIVERTER SPOUT IPS A918657 0070A HANDLE SCREW M916529 YYY0A LEVER HANDLE M907024 YYY2A INDEX BUTTON ARROW O ff H ot CHROME 002 SATIN 295 ...

Отзывы: