INSTALL HANDLE

ADJUST HOT LIMIT STOP

By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).

1

51

31

19

75

31

0

1

5

1

3

1

1

9

7

5

3

1

1

5

1

3

1

1

9

7

5

3

1

3

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

Turn CARTRIDGE STEM (2) to the OFF position (coldest setting)
before making adjustment to HOT LIMIT STOP (1). Use a
flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot
water temperature. Use ARROW (3) on CARTRIDGE (4) and
NUMBERS (5) on HOT LIMIT STOP (1) for indication.

1

5

1

5

4

4

3

3

2

2

1

2

3

4

Find correct position of HANDLE (1) and push
HANDLE (1) onto VALVE STEM (4).

Install HANDLE SCREW (2) and push in INDEX
CAP (3).

Check proper operation of HANDLE (1).

Turn on water supply on and test installed fitting.
Operate valve and diverter spout. 

A

1

INSTALL TRIM

When finished tiling the wall, remove PLASTER GUARD (A)
and turn off water supply.
 
Push CAP (1) over VALVE CARTRIDGE (2).

Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4).

Remove PIPE CAPS (5) from shower pipe and tub filler pipe.

Install SHOWER ARM with FLANGE (6) and SHOWER HEAD (7).

Install TUB FILLER SPOUT with FLANGE (8).

6

7

3

1

4

5

2

5

8

CAUTION: Protect finish on SHOWER ARM,
SHOWER HEAD and TUB SPOUT when installing.

SHOWER ARM
FLANGE

SPOUT FLANGE

Off

H

ot

Off

Hot

Содержание Bath/Shower Trim Kit T028.50X

Страница 1: ...T 5 7 8 INLETS 1 2 NPT OUTLETS 1 2 NPT OUTLETS 1 2 NPT 3 3 8 3 3 8 3 3 8 THREADED INLETS Required Tools Flat Blade Screwdriver Adjustable Wrench Channel Locks Plumbers Putty or Caulking Phillips Screwdriver FINISHED WALL 4 BOTTOM OF TUB 74 FOR HEAD CLEARANCE 5 1 8 REF 7 7 8 REF 18 OPTIONAL 5 REF 1 2 NPT 1 5 8 to 3 1 4 1 2 NPT 7 1 8 OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65 AND 80 TOP OF TUB RI...

Страница 2: ...tate counterclockwise one number to limit hot water temperature Use ARROW 3 on CARTRIDGE 4 and NUMBERS 5 on HOT LIMIT STOP 1 for indication 1 5 1 5 4 4 3 3 2 2 1 2 3 4 Find correct position of HANDLE 1 and push HANDLE 1 onto VALVE STEM 4 Install HANDLE SCREW 2 and push in INDEX CAP 3 Check proper operation of HANDLE 1 Turn on water supply on and test installed fitting Operate valve and diverter sp...

Страница 3: ...CK TO BACK INSTALLATION ROTATE 180 Remove PRESSURE BALANCE UNIT 5 Remove CAPS 7 and clean valve thoroughly Examine balancing unit and check condition of O ring on end of piston Piston should move back and forth Order Repair Part M952100 0070A if balancing unit is defective Replace CAPS 7 and install PRESSURE BALANCE UNIT 5 Make sure inlets line up with two holes in bottom of casting Top flange sho...

Страница 4: ...2 1902 Weekdays 8 00 a m to 8 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2004 M909732 YYY0A SPOUT ESCUTCHEON M950225 YYY0A DIVERTER SPOUT IPS A918657 0070A HANDLE SCREW M916529 YYY0A LEVER HANDLE M907024 YYY2A INDEX BUTTON ARROW O ff H ot CHROME 002 SATIN 295 ...

Отзывы: