American Standard Silver 302 and 303  Touchscreen Thermostat

 

Part No. 37-7775005

   09/2020   11-HD17D1-1C-EN 21

Energy Saving Factory Pre-Program

The 302 and 303 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this 
program suits your needs, simply set the thermostat clock and press the RUN key.
The table below shows the factory set heating and cooling schedule for all days of the week.

* Wake Up

(Morning)

Leave For Work

(Day)

* Return Home

(Evening)

Go To Bed 

 (Night)

Heating Program

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

Cooling Program

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

You can eliminate these two program periods in the configuration menu (reference #5) if the building is occupied all day. 

 

Day period will change to 6:00 AM and 70° and can be programmed as required.

10.  Planning Your Program – Important

The Heating and Cooling Program schedules provided allow you to pencil in your own program times and temperatures.
The 302 and 303 Thermostats come configured for 7 day programming and can also be configured for 5+1+1 programming (see 
configuration section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your own times 
and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day schedule, fill in all lines with the times and temperatures you want.

Keep the following guidelines in mind when planning your program.
• 

In Heating, lower temperatures will save energy.

• 

In Cooling, higher temperatures will save energy.

• 

If you plan on using Auto Changeover, do not program the heating temperature higher than the cooling temperature.

9.3  Enter the Heating Program

1.  Press the Menu key and then press Set Schedule.  
2.  Press SYSTEM key to select “Heat” in the system switch 

area indicating the active mode being   programmed.  You 
can switch to the other mode by pressing the system switch 
at any time.

3.  The top of the display will show the day(s) being 

programmed. The time and set at temperature are also 
displayed. “Morning” will also be displayed to indicate the 
period.

4.  Press 

 or 

 key to change the temperature to your 

selected temperature for the 1st heating period (Morning).

5.  Press   or   key to adjust the start time for period. 

The time will change in 15 minute increments.

6. 

Press FAN to select Auto or Prog.

7. 

After you have set the time and the temperature for the 
period to begin, press Set Schedule to advance to the next 
program period.

8. 

Repeat steps 2 through 6 until all of the program times and 
temperatures are set for all program periods on  that day. 

9. 

Press “Advance Day” to change to the next day and 
repeat steps 2 through 8.

10. 

When programming is complete and all of the times and 
temperatures match your desired heating schedule, press

11. 

Run Schedule. The thermostat will now run your program

9.4  Enter the Cooling Program

1. 

Press the SYSTEM key until the 

“Cool”

 icon appears.

2. 

Follow 

Enter Heating Program

 instructions for 

enteringcooling times and temperatures.

9.5  Automatic Schedule

Auto Schedule Heat is a fast way to program all the heating 
temperatures during the day to a comfortable temperature 
and then lower the temperature 6° at night. Auto Schedule 
Cool will program all of the cooling time periods to the same 
temperature. 

Note: Auto Schedule

 is available only when the thermostat 

is first powered on, after the thermostat has been reset, or 
anytime you turn 

AS

 on in the Configuration Menu (item 17 

AS Heat

 or 18 

AS Cool

). After use in heating and cooling, 

Auto Schedule

 on the display will change to 

Humidity

.

Heating Example:

1. 

In Heat mode, press Auto Schedule once.

2. 

Press   or 

 to select a comfortable day time temperature 

(example 72°). 

3. 

Press Auto Schedule again. Your thermostat is now 
programmed for 72° from 6:30 AM until 10:30 PM at 72°. At 
10:30 PM, your thermostat will set back 6° to 66°.

Содержание ACONT302

Страница 1: ...ANT This Document is customer property and is to remain with this unit These instructions do not cover all variations in systems or provide for every possible contingency to be met in connection with the installation Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to your install...

Страница 2: ...s lighting ballasts and large distribution panels Failure to follow these wiring practices may introduce electrical interference noise which can cause erratic system operation All unused thermostat wire to be grounded at indoor unit chassis ground only Shielded cable may be required if the above wiring guidelines cannot be met Ground only one end of the shield to the system chassis 1 Safety 2 2 Pr...

Страница 3: ... Heat Pump 1 2 F 1 7 F Emer Heat 0 6 F 1 7 F THERMOSTAT APPLICATION GUIDE Thermostat Configuration Options Thermostat Applications Maximum Stages Heat Cool Single Stage 1 No Heat Pump SS1 Gas Oil Electric Heat Only Cool Only or Heat Cool Systems 2 or 3 wire Hydronic Zone Hot Water or Steam Systems 24 Volt or Millivolt 1 1 Multi Stage 2 No Heat Pump MS2 2 2 Heat Pump 1 Single Stage Compressor Heat ...

Страница 4: ...the thermostat will cause damage to the unit 4 Place base over hole in wall and mark mounting hole locations on wall using base as template See Fig 1 5 Move base out of the way Drill mounting holes If you are using existing mounting holes and the holes drilled are too large and do not allow you to tighten base snugly use plastic screw anchors to secure the base 6 Fasten base snugly to wall using m...

Страница 5: ...ration required for remote sensor Call for cool No Output Cool mode 1st stage Blower Circulator fan energized on a call for cool or Fan On also energized in heating if configured for Electric Heat Installer Configuration Menu selects O or B for changeover function Set to O terminal energized in Cool Off mode Set to B terminal energized in Heat mergency mode Power closed connection for SPDT 3 wire ...

Страница 6: ...Installation and User Guide 6 Part No 37 7775005 09 2020 11 HD17D1 1C EN 5 Wiring Diagrams ...

Страница 7: ...American Standard Silver 302 and 303 Touchscreen Thermostat Part No 37 7775005 09 2020 11 HD17D1 1C EN 7 ...

Страница 8: ... remote indoor or outdoor wired sensor FOOTNOTES 1 A TCONT302 does not include humidifier HM and dehumidifier DHM terminals AC Cooling with GAF2 S Thermostat Thermostat Indoor Caution Do not run Outdoor Remote sensor wires in the same bundle with HVAC wires Also keep away from high voltage wiring to avoid interference Y B Outdoor ...

Страница 9: ...r HM and dehumidifier DHM terminals 2 Wire third party condensate overflow switches between Y of the thermostat and Y1 of the airflow control board 3 X2 is required for aux heat signal during defrost 4 Factory installed jumper 1 or 2 Stage Heat Pump with Variable Speed Furnace Caution Do not run Outdoor Remote sensor wires in the same bundle with HVAC wires Also keep away from high voltage wiring ...

Страница 10: ...Installation and User Guide 10 Part No 37 7775005 09 2020 11 HD17D1 1C EN ...

Страница 11: ...ze aux heat during defrost 4 Factory installed jumper Heat Pump with GAF2 S Thermostat Indoor Unit Outdoor Unit Caution Do not run Outdoor Remote sensor wires in the same bundle with HVAC wires Also keep away from high voltage wiring to avoid interference 1 1 2 4 3 G R B W1 O B L Y2 Y G Rc Rh C S HM W2 W E 6 DHM Optional remote indoor or outdoor wired sensor FOOTNOTES 1 A TCONT302 does not include...

Страница 12: ...age Unit with Variable Speed Blower Thermostat Thermostat Package Unit BK X2 Y1 G R B W1 O B L Y2 Y G Rc Rh C S HM W2 W E 6 DHM Optional remote indoor or outdoor wired sensor FOOTNOTES 1 A TCONT302 does not include humidifier HM and dehumidifier DHM terminals HP Package Unit with Non Variable Speed Blower Thermostat Thermostat Package Unit Caution Do not run Outdoor Remote sensor wires in the same...

Страница 13: ...y pad or to replace UV lamp 6 COPY key or INSTALLER CONFIG key 7 CLEAN DISPLAY key allows 30 seconds to wipe off the display or ADVANCE DAY key for programming 8 Used in programming to set time and in configuration menu to change selections 9 Hold Until indicates the time when a temporary hold period will end 10 Hours and Days displays during steps in installer configuration 11 The words Hold At a...

Страница 14: ...or HP2 is selected above 4 Days 7 P 5 or 0 Programs per week 7 days 5 1 1 days or non programmable 5 4 PS 2 Programs per day 4 Morning Day Evening Night 2 Day Night Not available if 4 is 0 6 Cool Off Heat Auto Cool Off Heat Heat Off Heat Cool Off Auto Off System switch configuration in non heat pump mode Cool Off Heat Em Auto Cool Off Heat Em Off Em Auto System switch configuration heat pump mode ...

Страница 15: ...POINT ON REFER TO THE SPECIFIC MODEL FOR THE CORRECT SCREEN REFERNCE NUMBER N A 38 80 bP 79 20 Selects Blower balance point Selection of 80 disables this feature This item appears if HP1 or HP2 is selected and outdoor sensor is installed and enabled N A 39 OFF Hd on Selects Humidity Display alternate with time N A 40 Humidity 00 Room Humidity 20 LO 20 HI Selects Humidity Display adjustment N A 41 ...

Страница 16: ...r up to five minutes 13 Select Continuous Display Lighting dL In low lighting conditions display backlight improves the display contrast 14 Select Temperature Display Adjustment 5 LO to 5 HI This allows you to adjust the room temperature display by 5 F to 5 F in 1 steps Your thermostat was accurately calibrated at the factory however you have the option to change the display temperature value to m...

Страница 17: ...orces additional heat stages to come on quickly when is used to raise the temperature a few degrees above the room Select this setting if you want the heat to increase quickly when you manually raise the temperature Selecting FA OFF allows the thermostat to calculate an optimal time to bring on additional stages of heat When the is used to raise the setting above the room temperature additional he...

Страница 18: ...ier is controlled by the thermostat It is recommended for use on flow through humidifiers only The display indicates CH Cycle Humidifier with the default indicating OFF Pressing the or keys will toggle the display from OFF to On and back to OFF When CH is enabled the humidifier will cycle to turn off for 10 minutes after it has run for 10 minutes The blower and or furnace will continue to run duri...

Страница 19: ...ey to select EM EM Heat Mode will flash on the display 8 Press to adjust thermostat setting above room temperature The Emergency heating system will begin to operate The display will show System On flashing EM Heat Mode and Heat to indicate that the Emergency system is operating 9 Adjust temperature setting to 3 above room temperature Any additional stages of auxiliary heat should begin to operate...

Страница 20: ...installer menu Then press Set Time once to indicate hour AM or PM designation in clock display 2 Press and hold either the or touch key until you reach the correct hour and AM or PM designation 3 Press Set Time again to display minutes only in clock display 4 Press and hold either the or touch keys until you reach the correct minutes 5 Press Set Time once again to display year 6 Press either the o...

Страница 21: ...system switch area indicating the active mode being programmed You can switch to the other mode by pressing the system switch at any time 3 The top of the display will show the day s being programmed The time and set at temperature are also displayed Morning will also be displayed to indicate the period 4 Press or key to change the temperature to your selected temperature for the 1st heating perio...

Страница 22: ...meters 300 feet Terminals S and on the terminal block allow connection of the remote sensor The thermostat must have 24 VAC Common connection to terminal C for the remote sensor to operate The remote sensor can be enabled or disabled in the Installer Configuration menu item 29 When remote sensor Remote is selected Off factory default no remote sensor is enabled When remote sensor is selected On th...

Страница 23: ...lected on the thermostat can monitor the outside temperature using remote sensor F145 1378 or use software logic to determine when to switch to gas heat and shut down the compressor This eliminates the need for a fossil fuel kit The user selectable temperature is called the dual fuel temperature setpoint dF and is set in the Installer Configuration menu items 33 or 34 With outdoor remote sensor in...

Страница 24: ...tantly 1 Possible short in wiring 2 Possible short in thermostat 3 Possible short in heat cool fan system 4 FAN Switch set to Fan ON Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal block Try resetting the thermostat as described above If the condition persists the manufacturer of your system or service person can inst...

Отзывы: