                                                                     OWNERS MANUAL

 

                                                                                                        

                                                                                                                                                  

 

 

 

 

ELECTRICAL INSTALLATION 

 

All electrical wiring must be installed in accordance with the National Electrical Code and with all 
local codes.  All wiring shall be done by a qualified electrician. Run one, two or three branch circuits 
(as required) from the main electrical service panel to the pump area of the framing structure to 
provide power to the unit.

 

 

Electrical components have specific wiring requirements. Refer to the matrix below for the electrical 
supply requirements for the whirlpool bathtub and factory installed components.   

 

Branch circuits must be rated for 110 – 120 volts.  Use 12 Gauge, 3 conductor cable for the circuits.  
If the length run exceeds 100 feet, check with local codes for requirements. Install moisture proof 
junction box(s) 6” above the floor at the pump end of the framing for each circuit.  
 

 

DO NOT INSTALL THE JUNCTION BOX(S) WHERE IT CAN BE REACHED WHILE SITTING OR 
STANDING IN THE TUB OR TOUCHING THE FAUCETS

 

WHIRLPOOL & AIR SPA CONFIGURATIONS FOR FACTORY INSTALLED COMPONENTS 

This section lists the factory installed components of the Whirlpool and/or Air Spa Systems. 

Note the required number of circuits and their rating for the Whirlpool & Air Spa unit you are planning to install. 

 

 

 

 

                                     CONFIGURATION LABEL FOR FACTORY INSTALLED COMPONENTS

 

 

Systems 

Electrical Rating   Circuit 1 

Electrical Rating   Circuit 2 

Soaker w / Quick Drain™ 

15 Amp GFCI 

  

Soaker w / Light 

15 Amp GFCI 

 

Soaker w / Quick Drain™ w / Light 

15 Amp GFCI 

  

Whirlpool or Air Spa 

15 Amp GFCI 

  

Whirlpool or Air Spa w / Light 

15 Amp GFCI 

  

Whirlpool or Air Spa w/ Quick Drain™ 

15 Amp GFCI 

15 Amp GFCI 

Whirlpool  or Air Spa w/ Light & Quick Drain™ 

15 Amp GFCI 

15 Amp GFCI 

Whirlpool  & Air Spa (Combo) 

15 Amp GFCI 

15 Amp GFCI 

Whirlpool  & Air Spa (Combo) w/ Light 

15 Amp GFCI 

15 Amp GFCI 

Whirlpool  & Air Spa (Combo) w/ Quick Drain™ 

20 Amp GFCI 

15 Amp GFCI 

Whirlpool  & Air Spa (Combo) w/ Light & Quick Drain™ 

20 Amp GFCI 

15 Amp GFCI 

 

IN-LINE HEATERS REQUIRE ITS OWN 15 AMP GFCI DEDICATED CIRCUIT 

 

 
All electrical connections must be carried out by a certified electrician in accordance with local electrical 
requirements and codes.  

Содержание 2651.110

Страница 1: ...WALK IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL...

Страница 2: ...now the owner of a walk in bathtub from the most trusted name in plumbing We thank you for your purchase Your American Standard walk in bath is a true investment in your health and peace of mind Cust...

Страница 3: ...ES OF THE INSTALLER Page 4 TESTING YOUR TUB BEFORE INSTALLATION Page 5 INSTALLATION PREPARATION Page 6 ELECTRICAL INSTALLATION Page 7 INSTALLATION PROCEDURES Page 8 9 SAFETY INSTRUCTIONS Page 10 OPERA...

Страница 4: ...nstallation related if not reported prior to installation Installers are also responsible for damage that occurs once the unit is placed in its niche NOTE Remove all packaging material except for the...

Страница 5: ...staller assumes all liabilities for installation procedures Although American Standard has taken reasonable precautions to ensure that the Quick Drain TM is suitable for residential plumbing it is the...

Страница 6: ...ion after tightening it may have been over tightened or might have a displaced O ring Disassemble it and make sure the O ring was seated properly Do the same if a leak persists at the heater Verify th...

Страница 7: ...ng feet to perfectly level the tub Note It is important that all 5 leveling feet are completely touching the floor and level for the door system to work properly 2 Check to ensure that the drain pipin...

Страница 8: ...HE FAUCETS WHIRLPOOL AIR SPA CONFIGURATIONS FOR FACTORY INSTALLED COMPONENTS This section lists the factory installed components of the Whirlpool and or Air Spa Systems Note the required number of cir...

Страница 9: ...mmended that the handheld be installed on the corner closest to the wall to prevent water from leaking off the deck and onto the floor 3 Install the optional in line water heater per manufacturer s in...

Страница 10: ...uld be installed on the tub before it is placed in the alcove Install the tile flange along all sides of the tub where the wall will be Measure to fit and miter cut the flange corners The flange shoul...

Страница 11: ...sciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your doctor before using the bathtub WARNING Risk of personal injury Risk of electric shock do not permit...

Страница 12: ...opens and closes jets above the seat which allows you to fill the tub half way and operate the lower whirlpool jets The Legs Massage valve must be closed when filling the tub half way and operating th...

Страница 13: ...use 12 There are no user serviceable parts located under the tub PURGE CYCLE All air blowers are equipped with a purge cycle to remove residual water from the lines The cycle will begin approximately...

Страница 14: ...r and clean away any hair lint or debris from the cover and housing then remount the cover in place Some suctions are not designed to be removed only suctions that have screws on the cover visible fro...

Страница 15: ...anty expressed or implied including any warranty of merchantability or fitness for a particular purpose shall apply after the warranty period described above This warranty does not cover defects or da...

Отзывы: