Medallion Dual Fuel Ranges
Use & Care Manual
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
6
The location selected for the range must meet the following criteria. If any of these criteria are not met, select another location.
SITE PREPARATION
0
The range is a free standing appliance. If the range is to be installed adjacent to cabinets, the clearances where indicated are
required.
0
This range may not be recessed into the cabinets. The rear of the oven door must be beyond the edge of the front-face of the
adjacent cabinet.
0
The gas and electrical supplies should be located below the unit or in the adjacent right cabinet.
0
Any openings in the wall behind the range and in the floor under the range must be sealed.
0
Always keep the appliance free and clear of combustible materials, gasoline, or other flammable vapors and liquids.
0
Do not obstruct the flow of combustion exhaust and ventilation air to the unit.
ELECTRICAL CONNECTION
0
The Range must be electrically grounded in compliance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA70.
0
The electrical service in the building must be equipped with a properly grounded NEMA 14 - 30 receptacle.
POWER REQUIREMENTS FOR THIS RANGE
0
240 VAC, 60 Hz, single phase, 30 AMP Max
GAS CONNECTION
Be certain the appliance being installed is correct for the gas service being provided. Refer to the appliance data plate for the gas
supply requirements.
A manual gas shut-off valve must be remotely installed and easily accessible in the adjacent cabinet. The regulator inlet is for a 3/4
inch gas line. The appliance ships with a 1/2 inch to 3/4 inch adapter connected to the regulator.
0
Use at least a 1/2" commercial flex hose to connect range to the gas supply (service line).
0
A manual gas shut-off valve must be installed, in easy access in front of the gas supply (service line) and ahead of the range for
safety and ease of maintenance.
0
All valves must be in the OFF position before connecting to the gas supply line.
INSTALLATION INSTRUCTIONS