OWNER’S MANUAL
SPECIFICATION
Q U A L I T Y P R O F E S S I O N A L C O O K I N G E Q U I P M E N T
Product Type:
Commercial Deep Fat Fryer
Brand Name:
American Range
Product Type:
AAF - Series Fryer
Manufactured By:
American Range Corporation
Distributed By:
Stoddart
www.Stoddart.com.au
Certificate No.:
DESCRIPTION
Heavy Duty Commercial Deep Fat Fryer manufactured in Stainless Steel outer panels and incorporating a stainless steel pan in either single or double or triple pan units.
Heating of the unit is by means of cast in-shot burners firing into separate combustion tubes. The burners are located behind the access door and positioned by the gas
injectors on the gas manifold and held secured by locating bolts. The fryer has a “V” shape base to collect frying particles and is equipped with flame failure and over
temperature control. The temperature of the oil is thermostatically controlled. The splashback incorporates the flue system from the in-shot burner tubes. The flue outlet at
the top of the splachback deflects the product of combustion products from the rear walls. The outer panels are mounted off a sub frame, NB each unit has a separate inlet
and regulator which is incorporated with combination flame failure valves. The unit is supplied with four adjustable legs x 150mm high or casters.
EXTERIOR PANELS:
304 X 1.2 Stainless Steel
SUB FRAME:
1.2 mm Square Base
FRY PAN:
2.0 mm Stainless Steel
REAR PANEL:
1.2 mm Aluminized Steel
BURNER IGNITION:
By pilot light mounted between 2 R/H burners x 68mm down from top of burner x 8mm from L/H center burner x 95 in. from front.
Refer to drawings for details.
THERMO-COUPLE ASSEMBLY: Alpha brass - TE 7 REF
PILOT:
Alpha brass - B13H5-HKF and B13H5-NG
INTERRUPTER LEADS:
1 set-Part No: IL-019
HEATING OF UNIT
Is by means of cast iron ported burners vertically mounted off the gas outlet manifold from the combination gas control with ported burners face at right angles firing into
the combustion tube through the body of the fryer tank. Refer to details showing burner mounting over injectors.
Number of Injectors (Orifice Hood)
NAT Gas
x3 Off
ULPG
x3 Off
NAT Gas
2.64mm @ 90Mj/h
ULPG
1.50mm @ 72Mj/h
Primary Aeration:
Through Venturi Inlet
Aeration Control of Burner:
Burner Fixed
Burner Support:
Provided off gas manifold located over injectors.
Vessel Clearance:
Fixed by firing into in-shot burner tubes.
1
3
13592 Desmond St. Pacoima CA 91331
Tel: 818.897.0808
www.americanrange.com
Imported by Tom Stoddart Pty Ltd
1300 79 1954
www.stoddart.com.au