American Range AAF-25W Скачать руководство пользователя страница 10

   OWNER’S MANUAL

    SERVICE

Q U A L I T Y   P R O F E S S I O N A L   C O O K I N G   E Q U I P M E N T

CLEANING STAINLESS STEEL SURFACES (CONTINUED)

To remove grease and food splatter or condensed vapors that have baked on the equipment apply cleanser to a damp cloth or sponge and rub cleanser on the metal in the 

direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible, in the direction of the polished lines will not mar the finish of the stainless steel. NEVER 

RUB WITH A CIRCULAR MOTION. Soil and burnt deposits that do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH-

BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL WOOL, as any particles left on the surface will rust and further spoil the appearance 

of the finish. NEVER USE A WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS. Surfaces that are marred will 

collect dirt more rapidly and become more difficult to clean. Marring also increases the possibility of corrosive attack. Refinishing may then be required.

Darkened areas, called “heat tint,” sometimes appear on stainless steel surfaces where the area has been subjected to excessive heat. These darkened areas are caused 

by thickening of the protective surface of the stainless steel and are not harmful. Heat tint can normally be removed by the above cleaning techniques, but tint which 

does not respond to that procedure calls for a vigorous scouring in the direction of the polish lines, using SCOTCH-BRITE scouring pads or a STAINLESS scouring pad in 

combination with a powered cleanser. Heat tint action may be lessened by not applying or by reducing, heat to equipment during slack periods.

All units are adjusted at the factory. In case of problems in operation at initial installation, check type of gas and manifold pressure and compare with information listed on 

the serial plate.
A mill voltage circuit diagram is located inside the front door of the fryer.

CHECKING AND ADJUSTING MAIN BURNERS

The main burners should burn with a steady blue flame, and the inner cone of the flame from each port should be about 3/4” long.
The flame from each main burner should enter each heat tube without touching the front of the fry pot or the sides, top, or bottom of each tube.

FOR AUTHORIZED SERVICE TECHNICIAN ONLY

!

WARNING

!

NOTICE

Adjustments and service work may be performed only by a qualified technician who is experienced in, and knowledgeable 

with, the operation of commercial gas cooking equipment. However, to assure your confidence, contact your American 

Service Representative for reliable service, dependable advice or other assistance, and for genuine factory parts..

Warranty will be void and the manufacturer is relieved of all liability if: (A) Service work is performed by other than a qualified 

technician OR (B) Other than approved American Range replacement parts are installed.

Yellow Tips

(Too little air or too much gas)

Blowing or Lifting Flames

(Too much air)

Normal Flame

9

13592 Desmond St. Pacoima CA 91331 
Tel: 818.897.0808 

www.americanrange.com

 

Imported by Tom Stoddart Pty Ltd 

1300 79 1954 

www.stoddart.com.au

 

Содержание AAF-25W

Страница 1: ...ained by consulting the local gas supplier All ULPG fryers must have a regulator installed between the gas tank H P and the fryer To be supplied by others If a the fryer is installed without the corre...

Страница 2: ...13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au OWNER S MANUAL...

Страница 3: ...an replacement parts are installed Be sure this Operator s Manual and important papers are given to the proper authority to retain for future reference DANGER WARNING CAUTION NOTICE Fire Hazard for yo...

Страница 4: ...fryer is in operation Sever burns may be caused When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and...

Страница 5: ...t cleaning If the unit is to be set on non combustible flooring such as a concrete slab 76 mm minimum toe room must be provided to prevent restriction of the air opening in the bottom of the unit WARN...

Страница 6: ...will be needed Manometer DigitalThermometer Temperature Probe DC Millivolt Meter Installation and servicing of the equipment should be performed by authorized personnel only and to AS5600 STEP 4 GAS...

Страница 7: ...shortening 9 Once the fry pot is filled with oil or shortening set the thermostat to the desired temperature 10 Close door 11 For complete shut down repeat steps 2 4 FILLING THE FRYPOT 1 Close drain...

Страница 8: ...as high as 475 F or 246 C In the event the fryer shuts down due to this condition the oil must be cooled to below 400 F or 204 C before the pilot burner can be re ignited When the oil has cooled use t...

Страница 9: ...th a clean cloth 5 Close drain valve and strain the oil back into the fry pot through several thicknesses of cheesecloth or filter it out using a filter machine 6 Replace the basket support frame if a...

Страница 10: ...scouring in the direction of the polish lines using SCOTCH BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser Heat tint action may be lessened by not applying or by...

Страница 11: ...s are carefully calibrated at the factory i e the dial is properly set to control appliance temperatures accurately Only a qualified appliance service technician should perform this adjustment 1 To ch...

Страница 12: ...ded hooks to the mounted bracket on the wall Step 2 and the other to the eye bolt Steps 3 4 Cock Dial OFF PILOT ON Safety Magnet Pilot Outlet 1 4Tubing Pilot Adjuster Inlet Max Rated Pressure 14 W C 1...

Страница 13: ...bination gas valve is in OFF position Pilot gas not adjusted properly Gas supply to unit off Bad thermopile Dirty thermopile connections at combination gas valve or high limit Clogged orifice Draft co...

Страница 14: ...separate inlet and regulator which is incorporated with combination flame failure valves The unit is supplied with four adjustable legs x 150mm high or casters EXTERIOR PANELS 304 X 1 2 Stainless Stee...

Страница 15: ...tween burner tubes x 125 from left hand of pan Floor Heat shield located on base of unit 670 x 380 1 2 aluminized steel Thermostat Capillary 750mm from top edge of pan Location Centered between burner...

Страница 16: ...Y P R O F E S S I O N A L C O O K I N G E Q U I P M E N T AAF SERIES SPECIFICATIONS AAF 25W 40W 45W 15 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart...

Страница 17: ...TLE 13592 DESMOND ST PACOIMA CA 91331 82154 01 10 2017 DATE 2342 REVISIONS ECN REV DESCRIPTION DATE APPROVED 2342 C INITIAL RELEASE 1 24 2019 MS 29 30 28 5 3 27 26 25 24 22 23 21 20 19 18 17 16 15 11...

Страница 18: ...EMBLY 14 A23054 DRAIN PIPE EXTENSION 1 1 2 NPT 15 A13110 CIRCUIT INTERRUPTOR 16 A32048 KNOB TCTHERMOSTAT 17 82151 BRACKET T STAT HI LIMIT HOLDER CE 18 A10007 HI LIMITTHERMOSTAT 19 A50400 RXTHERMOSTAT...

Страница 19: ...OWNER S MANUAL 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Страница 20: ...A70699 01292019 REV N 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Отзывы: