B. THROUGH-THE-WALL INSTALLATION
NOTES: Chimney height should not exceed 30 feet for
through-the-wall installations (see Figure 26).
We recommend enclosure of exterior-
mounted chimneys below the roofline in
geographical areas experiencing sustained
low-ambient temperature to help reduce or
limit condensation, creosote build-up and
poor draft. Also install an access door into
the enclosure for cleaning and maintenance.
1.
Make Opening In Wall
Be sure to maintain minimum of 2-inch airspace
clearance to combustibles.
a. Locate position on wall where chimney tee is to be
installed.
b. Cut a square opening through wall per Table 2.
2.
Install Wall Thimble
Cat. No. 6, 8 HS-WTP
a. Install the wall thimble through opening in wall with the
black painted surface on the inside wall (see Figure
22). Screw each trim plate in place through the four
(4) prepunched holes on each trim plate (see Figure
23). Use bead of high-temperature silicone sealant
between outer plate of thimble and exterior wall.
6
AmeriVent Model HS/HSS All-Fuel Chimney
Installation Instructions
2. Chimney Pipe Sections
Cat. No. 6, 8 HS/HSS-6, 12 18, 24 36, 48
See Section A.2., Page 2.
3. Chimney Cap, Storm Collar and Roof Flashing
See Section A.6., Page 4.
4. Chimney Connector Hook-Up
Connect the appliance to the chimney’s single-wall
adapter (see Figure 21) by using a minimum 24-gauge
single-wall connector pipe. Clearances from connector
pipe to combustible material shall be as specified in
Chapter 5 of the National Fire Protection Association
(NFPA) Standard 211.