1

Overview of the Hardware
Health Function SDK

The MegaRAC™ Hardware Health Function SDK
(Software Development Kit) is used with the MegaRAC™
(Remote Access Companion) card. It offers you a way to
monitor the hardware and measure items such as the
temperature, voltage, fans and chassis information.

The SDK utility generates the data that can be flashed onto
the MegaRAC card’s firmware using separate applications
such as RacView, WebRacView, Control Panel Applet
Utility, and the Remote Flash Utility. In order for all
monitoring features to work, the card has to be connected
to the baseboard though the Feature Connector or Hobbs
Connector.

You can customize the system health monitoring properties
by using the SDK utility to create configurations that
define how to monitor the hardware. For example, you can
set warning and alert limits for the voltage or temperature
and save them in the configuration. The system then uses
the settings in the configuration to measure the voltage and
temperature.

This SDK utility cannot be used to change the graphical
user interface (GUI) of the console program. After the
firmware has been updated, the data can be viewed through
the desired remote console program. The remote console
program automatically finds the monitoring parameters and
displays them appropriately.

Содержание MegaRAC

Страница 1: ...MegaRAC Hardware Health Function SDK MAN 780 HHF 8 30 00...

Страница 2: ...or written consent of the publisher American Megatrends Inc American Megatrends Inc acknowledges the following trademarks Intel is a registered trademark of Intel Corporation MS DOS and Microsoft are...

Страница 3: ...lth Function SDK 5 Using the MegaRAC Hardware Health Function SDK 6 Menu Screen 6 Adding Categories 7 Adding Functions 8 Adding Functions 9 HHF Parameters 10 HHF Access Script 14 HHF Script Example 15...

Страница 4: ...amages whether direct indirect special exemplary consequential or otherwise that may result from such error including but not limited to the loss of profits resulting from the use or misuse of the man...

Страница 5: ...ures to work the card has to be connected to the baseboard though the Feature Connector or Hobbs Connector You can customize the system health monitoring properties by using the SDK utility to create...

Страница 6: ...the other configuration screens used to select settings and create configurations The menu screen is shown below HVL and HHF The Hardware Health Function HHF and Hardware Virtualization Layer HVL are...

Страница 7: ...MegaRAC card s firmware monitors the system hardware using a generic engine This engine uses the binary data generated by the SDK to monitor the system The binary data contains the information needed...

Страница 8: ...MegaRAC Hardware Health Function SDK 4 General Information Continued This Guide This guide describes the Hardware Health Function SDK screens and the tasks that you can perform on each screen...

Страница 9: ...The main menu screen is used to access other configuration screens and enter settings for temperature voltage fans and any other item you want to monitor Running the Hardware Health Function SDK The H...

Страница 10: ...information and voltages Within each category you can select the Add Function tab to create functions to monitor individual elements such as the temperature of a specific piece of hardware The Delete...

Страница 11: ...nfo loads the IPMI information created by the GetSDR utility Help displays the Hardware Health SDK help file Note The Delete Category button is inactive in the screen shot above A category must be sel...

Страница 12: ...tion SDK 8 Adding Categories Continued Adding Functions To add a function select a category in the Health Function Tree then click the Add Function button The Health Function Porting Form screen Wizar...

Страница 13: ...on 9 Adding Functions Enter information in each section of this screen This screen is explained later in the following pages The Add Edit button located in the lower right corner displays the Access S...

Страница 14: ...Refer to Appendix B Application Notes for AMI MegaRAC Unit Description The item being monitored Conversion Formula This defines how the sensor data is converted to values that you can use The sensor d...

Страница 15: ...ecified warning limit the administrator is notified You can also set critical limits for the temperature Critical limits are higher and lower than the warning limits An example is shown below Add Edit...

Страница 16: ...re AND logical conjunction OR logical inclusion and XOR exclusive OR An exclusive OR yields true only if one operand is true and the other is false Final Access In the Final Access section you can cho...

Страница 17: ...e type of data Signed Byte Unsigned Byte Signed Word Unsigned Word Signed Dword double word Unsigned Dword Script Table The selections that you make in the first six sections on this screen are combin...

Страница 18: ...ess from hardware or read from the data supplied by the user For example primary hardware access can be of a type of hardware Read Port and a method either I2C Standard I O or Memory mapped I O This a...

Страница 19: ...od Select I2C slave ID as the Port value Set the value as 0x2C Enter 0x20 LM78 temperature register in the Local Data field Select unsigned byte as the data type Select Write Back To Port as the Final...

Страница 20: ...ing dialog box displays Click Yes to delete the category The category will no longer display on the Health Function Tree Deleting Functions To delete a function select a function in the Health Functio...

Страница 21: ...MegaRAC Hardware Health Function 17 Initializing Hardware To initialize the hardware select the Initialize Hardware button The Access Script Form screen displays Make your selections on this screen an...

Страница 22: ...lick on a function in Health Function Tree The Health Function Porting Form screen displays Move the cursor to any fields you want to change and enter the new information To change an access script cl...

Страница 23: ...ata Records Utility Version 1 0 For the following please refer to IPMI Sensor Data Record Formats Output all Sensor Data Records SDR to file 1 Create SDR file for MrSDK sdr 2 Output to Screen 3 Return...

Страница 24: ...rSDK utility The main menu screen displays 2 Click on the Import IPMI Info button A directory of files displays 3 Locate the IPMI sdr file and click on the Open button 4 Click on the Save Configuratio...

Страница 25: ...t X X 0 05 1000 Critical low limit X X 0 1 1000 Critical high limit X X 0 1 1000 2 New versions of the MegaRAC firmware include the following features that increase the flexibility of SDK The followin...

Страница 26: ...e checked This makes it possible to only set a lower limit that is greater than zero Fans usually have only a lower limit c If a Lower Limit is less than zero and equal to the associated Upper Limit t...

Страница 27: ...2 G General Information 3 Generating a SDK port for a Server with IPMI 19 H Hardware Health Function 2 Hardware Virtualization Layer 2 Health Function Porting Form 18 HHF Access Script 14 HHF Paramete...

Страница 28: ...MegaRAC Hardware Health Function SDK 24 T Thresholds 11 U Unit Description 10 User Data hex 13 Using HHF 5 W Warning high limit 21 Warning low limit 21 Wizard interface 8...

Отзывы: