Running a Test Program
Before programming the interrupter, you can test the interrupter by running a test program.
With the main menu displaying, press
to display and begin the Test Mode. Press
PREV
to cancel
the test or when the test is done.
Figure 4-1. Test Mode
The following list describes the type of information shown on the Test Mode screen and that is used
for the test:
l
TEST MODE ON/OFF/DONE
— The cycle that the interruption is running during the test. The
test runs through an off and on sequence for a few seconds. It will then display
DONE
when it
completes the test. The plug symbol indicates that power is present.
l
Switch: Norm Open
— Shows whether the relay is normally open or normally closed. The
setting is determined by the
Switch
setting in Out Parameters (refer to
).
l
Synch
— Shows that synchronization begins with On. The setting is determined by the
Int.
Cycle
setting in Out Parameters (refer to
).
l
CYCLE 1s ON, .5s OFF
— The timing of the on and off cycle.