Mid Stop Program
– There are two program selections that can be made, see below.
Program 0 = Disables the Mid Stop Function
Program 1 =Enables the Mid Stop function. This will open and close the
door to the preset values that are set in the Mid Stop Slow Down and
The Mid Stop, Stop set points. If the door is stopped at the mid stop
position and it’s given an open command by input 1 (Open Pushbutton)
the door will full open.
Mid Stop, Stop -
Move the door to the desired full open position then
look at the value of the encoder. Enter that value into this field keeping
in mind that the door will not stop at this value, it will over travel so it’s a
good idea to subtract approximately 100 counts to allow for this.
Mid Stop, Slow Down -
Move the door to the desired mid stop slow down
position then look at the value of the encoder. Enter that value into this
field keeping in mind that the door will not stop at this value, it will over
travel so it’s a good idea to subtract approximately 100 counts to allow
for this.
•
This is only used when the Mid Stop Program in Enabled.
Safety Edge Bypass –
Enter here the value at which the safety edge input
is disabled during the closing cycle. This should be a value right before
the door comes in contact with the floor. This is to disable the edge
input when it contacts the floor.
Aux Input Dead Band Timer – (00.0s)
– Depending on the device which
the Auxiliary Open input is controlled, false triggers may occur, or a
settling time may be required before the input is stable. This timer
provides a way to filter out false triggers.
M
*