american flame AF-LMF-RV Скачать руководство пользователя страница 8

REV. 11-30-18 Page 8

American Flame: AF-LMF Series Valve Kits

PARTS LIST

1.  Manual  Valve Assembly

AF-LMF

2. Gas Valve with Solenoid and ON/OFF Remote Assembly

AF-LMF-R

3. Gas Valve with Solenoid and Touch Screen Remote Assembly

AF-LMF-RD

4. Gas Valve with Step Motor and HML Remote Assembly

AF-LMF-RVS 

5. Gas Valve with Motor Drive and HL Remote Assembly

AF-LMF-RV

6.  10-inch Black Stainless Flex Connector

T102-9898-10

7.  Damper Stop

685-14

8.  PSE Pilot Assembly

2385-9P

9.  3/8” Flare x 3/8” NPT Connector

685-22

10.  Receiver Shield 

RS-1A

11. 6-volt DC Receiver (For R, RD & RV Models)

UN3-RX

12. 6-volt DC Receiver (For RVS Model)

RCAF-1035RX

13. ON/OFF Transmitter (AF-LMF-R Model)

CON1001TX

14. ON/OFF Transmitter (AF-LMF-RD Model)

5001TX

15. ON/OFF Hi/Med/Lo Transmitter (AF-LMF-RVS Model)

RCAF-1035TX

16. ON/OFF Hi/Lo Transmitter (AF-LMF-RV Model)

RCAF-1020-1TX

17. 12-volt Battery (1 Required for AF-LMF-R, RV & RVS Transmitters)

BATT12VOLT

18.  AA Battery (4 Required for AF-LMF-R & AF-LMF-RD receivers)

BATTAA

19.  AAA Battery (4 Required for AF-LMF-RD Transmitter)

BATTAAA

20. 3/8” to 1/2” adapter (increases 3/8” flare fitting to 1/2” flared fitting)

UR3-68

ON

OFF

REMOTE

OFF

LEARN

ON

OFF

OFF

ON

1 2 3

5

6

9

8

12

13

16

15

(Attached to Valve)

4

10

11

14

ON/OFF

HML

ON/HI

OFF

LO

AA Batteries

AA Batteries

AA Batteries

AA Batteries

AAA Ba

ttery

AAA Ba

ttery

AAA Ba

ttery

AAA Ba

ttery

12-Volt 

17

18

19

20

Содержание AF-LMF-RV

Страница 1: ...your log set FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Be sure Flue Damper and Glass Doors are fully open when operating any vented gas log set Young children should be carefully supervised when they are in same room as the appliance Notice Please leave these instructions for the consumer Retain for future refe...

Страница 2: ...pplied with a UR3 68 adapter that provides an option to convert the inlet or outlet gas connection from 3 8 flare fitting to a 1 2 flared fitting Simply thread the UR3 68 on to the inlet outlet gas flared fitting as shown in Fig 1 Note No pipe joint compound or thread tape is necessary Ensure fittings are tight and test for gas leaks Top View Back of Valve Inlet UR3 68 Fig 1 Installing UR3 68 to t...

Страница 3: ...Contol Knob Metal Valve Box Damper Clamp Thermocouple Pilot Assembly Stainless Flex Line to Burner ON OF F Receiver Shield Transmitter Receiver ON OFF LEARN OFF ON REMOTE CON 1001 Metal Valve Box Damper Clamp Thermocouple Pilot Assembly Stainless Flex Line to Burner ON OF F Receiver Shield Transmitter Receiver LEARN OFF ON REMOTE OFF ON 5001 Metal Valve Box Touch Screen Damper Clamp Thermocouple P...

Страница 4: ...or over the burner pan 10 Turn ON gas supply and check all connections for leaks using soapy water solution 11 Follow valve pilot lighting instructions After pilot is lit check pilot fittings for leaks 12 Reinstall basket grate and logs 13 Install Damper stop supplied with this valve kit on edge of damper to prevent it from fully closing This allows damper to remain slightly open to allow the pilo...

Страница 5: ... OF THE BASKET GRATE AND NEVER PLACED DIRECTLY IN FRONT OR BEHIND THE BASKET GRATE Fig 10 Shows clearances to be maintained inside fire box Optional Valve Mounting Location Valve Box Kit 2 0 Min 2 0 Min 2 0 Min 2 0 Min Burner Pan Basket Grate 4 0 4 0 Optional Pilot Mounting Pilot Mounting Burner Pan Pilot Assembly Fig 9 Show side view of pilot assembly mounted on edge of burner pan 4 inche from en...

Страница 6: ...res 4 AA 1 5DC Volt Alkaline batteries Learning button Battery cover slides on off Fig 12 Installing batteries into receiver Fig 13 Step motor connection using the 4 Pin connector 4 Pin Female Connector 4 Pin Male Connector 4 Pin Female Connector 4 Pin Male Connector Receiver Back Step Motor LEARNING TRANSMITTER TO RECEIVER Ensure batteries are installed into the transmitter Each transmitter uses ...

Страница 7: ...clockwise to the ON position The main burner valve will open and the main burner will ignite TURNING OFF VALVE KIT 1 To shut OFF the main burner while leaving the pilot ON turn the gas control knob clockwise to the PILOT position This action will close the main gas flow 2 To shut OFF the main burner and pilot turn the gas control knob clockwise to the OFF position This action will close the main g...

Страница 8: ...12 6 volt DC Receiver For RVS Model RCAF 1035RX 13 ON OFF Transmitter AF LMF R Model CON1001TX 14 ON OFF Transmitter AF LMF RD Model 5001TX 15 ON OFF Hi Med Lo Transmitter AF LMF RVS Model RCAF 1035TX 16 ON OFF Hi Lo Transmitter AF LMF RV Model RCAF 1020 1TX 17 12 volt Battery 1 Required for AF LMF R RV RVS Transmitters BATT12VOLT 18 AA Battery 4 Required for AF LMF R AF LMF RD receivers BATTAA 19...

Страница 9: ...up before releas ing the black control knob See lighting instructions on page 7 2 Check the connection from the pilot assembly to the gas valve Follow the solid copper wire to the gas valve and ensure the fitting it snug and not too tight The connecton should only be installed finger tight plus a quarter turn with a wrench See Fig 16 for reference 3 Over time the thermocouple tip can get dirty wit...

Отзывы: