WARNING

This control system must be installed exactly as outlined in these instructions.  Read all instructions completely before attempting 

installation.  Follow instructions carefully during installation.  Any modifications of this control or any of its components will void the 

warranty and may pose a fire hazard.

These instructions must be used as a supplement to the instructions supplied with the gas log set. Follow the gas log instructions 

supplied by the manufacturers on the placement of the burner pan, log basket grate, burner media (sand or vermiculite), ember 

material and the log placement. Please follow these instructions on the connection of the inlet line to the gas valve and then to the 

burner pan assembly.

If your fireplace installation has glass doors, only operate the fireplace with glass doors in the fully open position.

INSTALLATION: VALVE KIT WITH PRE-EXISTING LOG SET

1.  Make sure primary gas supply is turned 

OFF

 to log set. Make sure you have a certified and approved shut-off within 6-feet of the 

fireplace, or follow local code requirements.

2.  Remove all logs and basket grate and set aside.

3.  Disconnect the existing manual valve from the inlet gas supply.

4.  Remove manual valve and fittings on existing the burner pan.

5.  Locate a position on the back of the burner pan about 4-inches from the right or left side of the burner pan to mount the pilot        

assembly (Figs. 8-10).

6.  Mount pilot assembly to burner pan as shown in Figs 8-9. Note this pilot bracket clips on the burner pan and holds the pilot at a 

45° position onto the pan with no screws required. A screw can be added to secure the pilot assembly if needed. Carefully bend 

1/4” pilot tubing from pilot assembly until the bottom of the pilot bracket is resting against the pan. (This will hold the pilot at the 45° 

position) then connect pilot fitting to valve. 

(Use caution when bending pilot tubing not to kink the tubing or locate the tubing 

in or over the burner pan)

.   

7.  Locate the valve kit in the right or left front corner of the firebox as far forward as possible to maintain clearances in Fig 10.

8.  Bend inlet gas supply line and connect the 3/8” flare fitting to gas valve 3/8” inlet connector

 (Use caution not to kink the line 

when bending).  Note:

 Use the UR3-68 adapter (if needed) for inlet or outlet gas supply as shown in Fig. 1.

9.  Bend 12” stainless flex line and connect to valve outlet then connect other end to 3/8” flare fitting on burner pan 

(Caution do not 

let gas inlet line to the valve kit or gas outlet line from the valve kit be placed in or over the burner pan).

10.  Turn ON gas supply and check all connections for leaks using soapy water solution.

11.  Follow valve pilot lighting instructions. After pilot is lit, check pilot fittings for leaks.

12.  Reinstall basket grate and logs.

13.  Install Damper stop (supplied with this valve kit)  on edge of damper to prevent it from fully closing. This allows damper to remain 

slightly open to allow the pilot exhaust to vent outdoors.

CAUTION: On all PROPANE installations it is recommended that an inlet pressure regulator be used.

INSTALLATION: VALVE KIT WITH NEW LOG SET

1.  Ensure primary gas supply is turned 

OFF

 to log set. Make sure you have a certified and approved shut-off within 6-feet of the     

fireplace, or follow local code requirements.

2.  Follow the instructions supplied with the log set to locate the burner pan. Using the fittings, orifice and gas supply line that came 

with the log set, connect the line to the inlet gas supply.

3.  Locate a position on the back of the burner pan about 4-inches from the right or left side of the burner pan (See Figs. 8-10).

4.  Mount pilot assembly to burner pan as shown in (Figs. 8-9). Note this pilot bracket clips on the burner pan and holds the pilot at a 

45° position onto the pan and no screws required. 

Note

: A screw can be added to secure the pilot assembly if needed. Carefully 

bend 1/4” pilot tubing from pilot assembly until the bottom of the pilot bracket is resting against the pan. (This will hold the pilot at 

the 45° position) then connect pilot fitting to valve. 

(Use caution when bending pilot tubing not to kink the tubing or locate the 

tubing in or over the burner pan)

5.  Locate the valve kit in the right or left front corner of the firebox as far forward as possible to maintain clearences (See Fig. 10).

6.  Bend inlet gas supply line and connect the 3/8” flare fitting to gas valve 3/8” inlet connector

 (Use caution not to kink the line 

when bending).  Note:

 Use the UR3-68 adapter (if needed) for inlet or outlet gas supply as shown in Fig. 1.

7.  Bend 12” stainless flex line and connect to valve outlet then connect other end to 3/8” flare fitting on burner pan (

Caution do not 

let gas inlet line to the valve kit or gas outlet line from the valve kit be placed in or over the burner pan).

8.  Turn ON gas supply and check all connections for leaks using soapy water solution.

9.  Follow valve pilot lighting instructions. After is pilot lit, check pilot fittings for leaks.

10.  Follow the instructions supplied with the log set to install ember material, basket grate and logs.

11.  Install Damper stop (supplied with this valve kit)  on edge of damper to prevent it from fully closing. This allows damper to remain 

slightly open to allow the pilot exhaust to vent outdoors.

CAUTION: On all PROPANE installations it is recommended that an inlet pressure regulator be used.

Содержание AF-LMF-RV

Страница 1: ...your log set FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Be sure Flue Damper and Glass Doors are fully open when operating any vented gas log set Young children should be carefully supervised when they are in same room as the appliance Notice Please leave these instructions for the consumer Retain for future refe...

Страница 2: ...pplied with a UR3 68 adapter that provides an option to convert the inlet or outlet gas connection from 3 8 flare fitting to a 1 2 flared fitting Simply thread the UR3 68 on to the inlet outlet gas flared fitting as shown in Fig 1 Note No pipe joint compound or thread tape is necessary Ensure fittings are tight and test for gas leaks Top View Back of Valve Inlet UR3 68 Fig 1 Installing UR3 68 to t...

Страница 3: ...Contol Knob Metal Valve Box Damper Clamp Thermocouple Pilot Assembly Stainless Flex Line to Burner ON OF F Receiver Shield Transmitter Receiver ON OFF LEARN OFF ON REMOTE CON 1001 Metal Valve Box Damper Clamp Thermocouple Pilot Assembly Stainless Flex Line to Burner ON OF F Receiver Shield Transmitter Receiver LEARN OFF ON REMOTE OFF ON 5001 Metal Valve Box Touch Screen Damper Clamp Thermocouple P...

Страница 4: ...or over the burner pan 10 Turn ON gas supply and check all connections for leaks using soapy water solution 11 Follow valve pilot lighting instructions After pilot is lit check pilot fittings for leaks 12 Reinstall basket grate and logs 13 Install Damper stop supplied with this valve kit on edge of damper to prevent it from fully closing This allows damper to remain slightly open to allow the pilo...

Страница 5: ... OF THE BASKET GRATE AND NEVER PLACED DIRECTLY IN FRONT OR BEHIND THE BASKET GRATE Fig 10 Shows clearances to be maintained inside fire box Optional Valve Mounting Location Valve Box Kit 2 0 Min 2 0 Min 2 0 Min 2 0 Min Burner Pan Basket Grate 4 0 4 0 Optional Pilot Mounting Pilot Mounting Burner Pan Pilot Assembly Fig 9 Show side view of pilot assembly mounted on edge of burner pan 4 inche from en...

Страница 6: ...res 4 AA 1 5DC Volt Alkaline batteries Learning button Battery cover slides on off Fig 12 Installing batteries into receiver Fig 13 Step motor connection using the 4 Pin connector 4 Pin Female Connector 4 Pin Male Connector 4 Pin Female Connector 4 Pin Male Connector Receiver Back Step Motor LEARNING TRANSMITTER TO RECEIVER Ensure batteries are installed into the transmitter Each transmitter uses ...

Страница 7: ...clockwise to the ON position The main burner valve will open and the main burner will ignite TURNING OFF VALVE KIT 1 To shut OFF the main burner while leaving the pilot ON turn the gas control knob clockwise to the PILOT position This action will close the main gas flow 2 To shut OFF the main burner and pilot turn the gas control knob clockwise to the OFF position This action will close the main g...

Страница 8: ...12 6 volt DC Receiver For RVS Model RCAF 1035RX 13 ON OFF Transmitter AF LMF R Model CON1001TX 14 ON OFF Transmitter AF LMF RD Model 5001TX 15 ON OFF Hi Med Lo Transmitter AF LMF RVS Model RCAF 1035TX 16 ON OFF Hi Lo Transmitter AF LMF RV Model RCAF 1020 1TX 17 12 volt Battery 1 Required for AF LMF R RV RVS Transmitters BATT12VOLT 18 AA Battery 4 Required for AF LMF R AF LMF RD receivers BATTAA 19...

Страница 9: ...up before releas ing the black control knob See lighting instructions on page 7 2 Check the connection from the pilot assembly to the gas valve Follow the solid copper wire to the gas valve and ensure the fitting it snug and not too tight The connecton should only be installed finger tight plus a quarter turn with a wrench See Fig 16 for reference 3 Over time the thermocouple tip can get dirty wit...