14
Installation Of Fire Pit Into An Approved Enclosure
REQUIREMENTS
1.
Only non-combustible materials should come in direct contact with any part of the Fire Pit. Underneath area should be
non-combustible as well.
2.
Only use ¾” gas supply line to the Fire Pit. Based on the selection of the fire pit size, the proper brass fittings should be
used to ensure a proper installation.
3.
Determine the size of the rectangle or linear Fire Pit you are preparing to install (Refer to page 3).
4.
You must provide a rectangle or linear cut out to place the fire pit into the non-combustible enclosure surround. Use the
pattern from the shipping carton for sizing.
5.
Follow the local code requirements for the gas type being used. This Fire Pit should be installed in accordance with local
codes and ordinances or in the absence of local codes, with the latest National Fuel Gas Code, ANSI Z223.1 NFPA54 or
CSAB149.1, Natural and Propane Installation Code in Canada.
6.
Fire Pits create high temperatures, it is very important to have any combustibles at a safe distance.
7.
Normal operation of the Fire Pit is with a battery box that is supplied with your system (Fig 4). The battery box has 12-
feet of black sleeved wire that is to be passed through the junction box provided. This wire should not be cut or spliced and
the junction box can be placed in the facing of the vertical finish of the fire pit, if you place the wire under ground you
should install those wires into an approved protective conduit/sleeve material.
8.
If (optional) 120VAC adapter (Pg.13) is going to be used to power this system it is required to follow all local codes or
National Electrical Code ANSI/NFPA 70 for installation of this electrical outlet. A breaker on wall switch with approved out
door outlet must be used to insure safety to this Fire Pit. When not in use the breaker should be in the OFF position.
9.
Fire pit should never be left unattended while in operation. It should always be a safe distance from all trees and
combustible landscape materials.
10.
Construction of the finished fire pit should be stable and solid. From the bottom of the control box that houses the gas
valve and module, it should be a minimum if of 4-inches to the ground level. See figure #1. Drainage is critical to ensure
that water does not damage and valve components. Never install the fire ring system below grade.
11. CAUTION: A minimum of 18 square inches of cross ventilation (2 sides) is required to keep the components in good
working order.
12.
The insulation square pad provided with the Fire Pit is to be placed foil up toward the bottom of pan on top of the valve
box.
13.
Never fill the cavity under and around the valve box with any material, this is a provided air space necessary for ventilation.
14.
These products are designed for outdoor use only. Not approved for any indoor use.
15.
This Fire Pit is designed to have decorative rock, Lava rock/Media covering the burner. Decorative Rock is not provided.
When purchasing decorative rock it is recommended to use minimum of 1-inch diameter rock as a base to fill the burner
pan. Decorative glass covering may be loosely scattered on top of rock if desired.
NOTE:
If using all glass media, glass
must be a minimum of 1/4-inch diameter or larger.
16.
Gas lines and fittings must be installed in to the non-combustible structure. All gas connections must be leak tested
before installation of the fire pit. Soapy water leak detection is required before regular use of the fire pit.
17.
Do not use material that will absorb moisture overtime and will not release this moisture quickly. Moisture can boil in this
material and can rapidly break apart and cause damage or personal injury.
18.
Never leave any other combustible material on top of the fire pit. This could cause unsafe operation of this system and
damage to the component that will not be covered under our warranty.
19.
Cover the complete burner with lava or decorative Rock material (min. 1-inch diameter). Completely cover the burner, no
more than 1 inch above the burner.