M
l
attachment is in the square driver of the mixer. Secure the attachment by tightening the
thumbscrew. Be sure to follow the manufacturer’s installation, operation, and safety instructions for
the hub attachment.
Attachment hub should not be used while mixing.
MAINTENANCE
NOTE : ALL MAINTENANCE WORK SHOULD BE DONE ONLY AFTER UNIT HAS BEEN
DISCONNECTED FROM ELECTRICAL POWER AND GROUNDING.
General
Clean the mixer after each day’s use. It should be wiped with a clean, damp cloth. Use a soft brush to clean
areas that are difficult to clean with a cloth.
NEVER USE A METAL OR OTHER TYPE OF STIFF BRUSH
TO CLEAN THE MIXER. NEVER CLEAN THE MIXER WITH A WATER HOSE OR ANY TYPE OF FLUID
UNDER PRESSURE OR IN HIGH QUANTITY.
Daily
z
Clean the mixer regularly after each day’s use.
z
Do not run the mixer continuously for long periods.
z
Wash the bowl, agitators, and attachments according to normal food-contact equipment procedures
after each use.
Weekly
z
Inspect planetary mechanism and transmission case for leaks or damage.
CONTACT YOUR LOCAL
SERVICE REPRESENTATIVE IF IT BECOMES NECESSARY TO REPACK THE BALL BEARING
.
Use of unapproved grease or lubricants may lead to damage and may void the manufacturer’s
warranty.
Periodic
z
Lubricate the bowl lift semi-annually, or more often under heavier use.
z
Inspect the drip cup periodically for moisture or lubricant dripping. Remove the cup and wipe it with a
soft cloth.
Lubrication
z
The mixer comes with
grease-packed ball bearing and/or roller bearing
that do not require regular
lubrication. When it becomes necessary to repack them, contact your authorized service representative
or AMERICAN EAGLE.
z
The
bowl slideways
require periodic lubrication with a small quantity of high-quality mineral oil that
may be applied with a cotton swab or by finger tip.
z
The polished drip cup protects against lubricant seeping out of the planetary into the bowl. The drip cup
should be wiped clean monthly and inspected for excessive leakage. The drip cup may be removed by