![American Dynamics RASI series Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/american-dynamics/rasi-series/rasi-series_installation-manual_2924093003.webp)
1
SpeedDome Optima Outdoor Installation Guide
RASO Series
2
= Step Prevents
Before performing these steps, ensure power
is off and read additional information attached
for important details and warnings!
Water Intrusion.
Green Connector
(Power)
Black Connector
(Data)
Gray Connector
(Relay)
Manchester
SensorNet
RS-422
3
A
A
C
B
B
Check o-ring
is properly set.
Turn until no threads
are exposed.
Keep cables from
twisting while turning
housing.
IMPORTANT!
This housing meets IP66/Nema 4
ratings provided it is used with a properly installed
ROENDC End Cap Assembly and one of the following
mounts: RHOTR Over-the Roof Mount, RHOSW Short
Wall Mount, or RHOLW Long Wall Mount.
Thread cables through
end cap assembly
and attach housing to
mounting structure.
Attach cable connectors
(in kit 0351-1686-01).
Pin 1 - 24Vac
Pin 2 - Common
Pin 3 - 24Vac
Pin 1 - NC
Pin 2 - Common
Pin 3 - NO (3.5mA sink)
Pin 4 - Alarm return
Pin 5 - Alarm input (3.5mA sink)
Pin 1-4 - Not used
Pin 5 - White
Pin 6 - Black
Pin 1-4 - Not used
Pin 5 - Orange
Pin 6 - Yellow
Pin 1 - Orange
Pin 2 - Green
Pin 3 - Yellow
Pin 4 - Brown
Pins 5-6 - Not used
Make connections,
insert cables into
end cap assembly,
and attach cover.
Ensure black foam plug is around
cable and press-fit into pipe.
At end of pipe.
See A, B, C.
A
B
C
Line up.
Push to line
and maintain
compresion.
Tighten
Ensure seal and sleeve
are properly set.
Seal
Sleeve
8000-2692-01, Rev. E
Page 3 of 18