Before You Begin 

To ensure a smooth and successful installation, 
observe the following requirements. 

General Requirements 

  Have electrical work comply with latest national 

electrical code, national fire code, and all 
applicable local codes and ordinances.  

  Coordinate work with other trades to avoid 

interference. 

  Verify existing site conditions and coordinate 

with the owner’s representative and appropriate 
utilities as required. 

  Obtain copies of all related plans, specifications, 

shop drawings and addenda to schedule and 
coordinate related work. 

  Thoroughly review the project to ensure that all 

work meets or exceeds the above requirements. 
Bring alleged discrepancies to the attention of 
the CCTV Project Coordinator.  

Mounting Requirements 

Mounting space: Ensure there is the following 
space above the ceiling to accommodate the 
dome.  

Height above ceiling: 

170mm (6.7in)

 

Diameter: 192mm (7.5in) 

Structural members: Verify that ceiling members 
can support the camera dome and mounting 
structure, if used. 

Weight: 2.5kg (5.5 lbs) 

Cable Requirements 

Data cables:

 The following table shows cable 

requirements for SensorNet, RS-422 and 
Manchester networks. For more information about 
communication protocols and cable networks, see 

Communication Protocols and Cable Networks

8000-2573-19.  

Data cable requirements 

 

SensorNet 

RS-422 
Simplex Manchester

Cable type 

1 unshielded, 
twisted pair* 

1 shielded, 
twisted 
pair* ** 

1  
shielded 
twisted 
pair*** 

Wire gauge 

22 AWG 

22AWG 

18 AWG 

Connection Non-

polarized 

Polarized Polarized 

Max. devices 
per cable run 

32 10 

*  Power, data, and video cables can be ordered separately or 

within a composite cable that can be ordered in various 
lengths. Plenum-rated cables must be used in indoor 
ceilings used for environmental air return (called "other air 
space" in the National Electrical Code). Order parts through 
your distribution network.  

Note:

 If you order cable from an outside source, wire colors 

may be different. 

**  The RS-422 Simplex connection only uses a single twisted 

pair allowing the dome to receive only. RS-422 transmit 
from the dome is not supported.  

***  Belden 88760 (plenum), or Belden 8760 cable (non-plenum) 

cable is recommended. Plenum-rated cables must be used 
in indoor ceilings used for environmental air return (called 
"other air space" in the National Electrical Code). Order 
cable directly from Belden by calling 1-800-235-3361. 

Plenum ceilings:

 Cable must be rated for plenum 

or routed through flexible conduit. A cover plate for 
the dome accepts ½" conduit. 

WARNING!

 Do not run cables adjacent 

to or in the same conduit as line voltage 
mains power. 

Power cables.

 Make power cable lengths as short 

as possible to minimize the affects of low line 
voltages and outdoor cold temperature 
performance.

 

Maximum cable length between a 

Class 2 LPS (low voltage) ac source, such as a J-
box, and the dome depends on the ac line voltage. 
See the tables below for maximum cable lengths 
based on the worst-case low line voltages. 
The line voltage must not go below the voltage 
shown for the dome to be able to power up and 
operate at the corresponding distances shown. 
Typically cable distances are used that provide a 
15% margin between nominal and low line 
conditions. For example, if the nominal voltage 
measures 120Vac, restrict the cable length to the 
distance for .85 x 120 or approximately 100Vac. 

 

Содержание RASEL Series

Страница 1: ...late instructions for the plate are supplied separately CAUTION Save the box and packing materials These materials are required should you need to ship the dome to a repair center Note The dome accepts either cable or conduit If running cable through a plenum ceiling either plenum rated cable or flexible conduit is required 2006 Sensormatic Electronics Corp Contents Warnings 2 Before You Begin 3 I...

Страница 2: ...tended to be powered from a Limited Power Source A limited power source is a certified source of SELV and if inherently limited with 8 amps maximum output current and a maximum of 100VA available or if not inherently limited fused with a maximum value of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through Sensormatic or through another ...

Страница 3: ... Max devices per cable run 32 10 3 Power data and video cables can be ordered separately or within a composite cable that can be ordered in various lengths Plenum rated cables must be used in indoor ceilings used for environmental air return called other air space in the National Electrical Code Order parts through your distribution network Note If you order cable from an outside source wire color...

Страница 4: ...tion at the other end of the cable The figure below shows twisted pair cable connections See installation guide 8200 0298 01 for details Table 1 Maximum cable length and worst case low line voltages Indoor Dome Worst Case Meters AC Power Source Low Line V Feet 28 VA 117 130 425 Transformer 100 80 250 5604 0006 01 90 60 200 50 VA 117 160 525 Transformer 100 100 325 5604 0044 01 90 60 200 1 position...

Страница 5: ...RS 422 1 99 For example for address 107 set SW3 to 1 SW2 to 0 black dot and SW1 to 7 Compatibility with the VM96 Controller If using a VM96 controller the controller must be Version 5 2 or higher Power Up Routine After power is connected to the dome the dome performs a homing routine During the homing process the camera will pan and then either Go to the start point of the apple peel pattern or If...

Страница 6: ... Polarity 2 No Polarity Manch 1 WHT 2 BLK Comm P9 Video 24Vac P10 RS422 Switch 6 7 Off all others On 8 On Off 7 6 5 4 3 2 1 RS422 1 Rx 2 Rx 4 Set address switches SW1 SW2 and SW3 for the address for example 001 016 for VM16 001 096 for VM96 5 If daisy chaining domes the dome furthest from the video controller requires that termination switch S1 remain in the terminated position resistor symbol All...

Страница 7: ...ighten the connector screws DO NOT over tighten the connectors 13 Plug video or Twisted Pair Adapter power and data communications cables into their mating connectors in the top of the dome housing WARNING Ensure power is off at the source when connecting cables Otherwise the dome will operate during installation 14 Reattach the cover plate to the dome housing 15 Using safety wire attach the dome ...

Страница 8: ...the last position in memory Once the camera stops the camera is online and is ready to be controlled Also green red and yellow LEDs will light in various patterns to indicate status Typically you do not need to view these LEDs unless a failure occurs during or after the routine See Troubleshooting for an explanation of the LED patterns 19 Once the homing routine completes affix the bubble to the d...

Страница 9: ...d and yellow LEDs through the housing LED Indication Cause Yellow blinks Wiring OK Red flickers Green blinks RS 422 wired backwards Red blinks Green flickers A wire is not connected Fix wiring 2 Reset the dome to the desired address No video 1 Check the video cable and its connection to the dome If not OK fix or replace the cable 2 Check the iris setting Open iris or set to auto iris 3 If the prob...

Страница 10: ...ble Assembly Clear 0100 2458 01 6 Bubble Assembly Smoked 0100 2458 02 Tilt Assy 0400 1207 01 NTSC 02 PAL 7 Base Tilt 0500 9110 01 8 Gear Camera Base 0500 9112 01 9 Tilt Upright 2 0500 9168 01 10 Camera 1 4 CCD NTSC STD 22XM 2003 0049 01 11 Camera 1 4 CCD PAL STD 22XM 2003 0049 02 12 Timing Belt 2500 0041 01 13 Tilt Motor with Pully 3501 0028 01 14 PCB Tilt Sensor 0312 1524 01 15 Ribbon Cable 20mm ...

Страница 11: ...SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200 0181 01 REV E INSTALLATION AND SERVICE GUIDE 11 of 14 8 12 9 17 16 19 20 Tilt Assy 0400 1207 01 02 Base Assy 0404 0008 01 18 7 13 14 15 10 11 ...

Страница 12: ...l Noise 50dB typical Minimum illumination 1 0 lux 20 IRE Gain control Automatic AGC White balance Through the Lens TTL Automatic Tracing White Balance ATW NTSC version Pickup device 768 H x 494 V pixels Scanning 525 lines 60 fields 30 frames Horizontal 15 734kHz Vertical 59 9Hz PAL version Pickup device 752 H x 582 V pixels Scanning 625 lines 50 fields 25 frames Horizontal 15 625kHz Vertical 50Hz ...

Страница 13: ...r node Node repeaters SensorNet junction boxes Cable topologies Daisy chain Backbone Star Transmission medium Single non polarized unshielded twisted pair UTP 22AWG Wire configuration Single unshielded twisted pair UTP 22AWG non polarized Connector Plug in Euro style terminal block 5 08mm Terminating resistor 120 ohms switch selectable EIA 422 Communications Network Distance 1km Maximum Loads 10 n...

Страница 14: ... very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose NOTICE ...

Отзывы: