SpeedDome Ultra III Camera Dome
8000-2573-01, Rev. B
INSTALLATION AND SERVICE GUIDE
25
Removing the Camera
1. Perform procedure “Removing the Slot
Covers” (page 24).
2. Remove ribbon cable from camera (Figure
22).
Swivel camera yoke to expose camera
connector. Then, using a small slotted
screwdriver, 1) gently pry camera connector
loose from camera, and 2) pull it down through
cable tie wrap.
Figure 26. Removing the ribbon cable
2
1
3. Remove camera (Figure 27).
1) Loosen the screw holding the camera tripod
mount, then 2) carefully lift the camera out.
Figure 27. Removing the camera
1
2
Reverse steps to reassemble. Ensure ribbon cable
pins are inserted “face down”.
Detaching the Eyeball
1. Perform procedure “Removing the Slot
Covers” (page 24).
2. Perform procedure “Removing the Camera”
(this page).
3. Detach eyeball from housing (Figure 28).
a. Turn yoke to access tabs. One tab is more
accessible than the other. Use your finger
to press this tab while, simultaneously,
using a small slotted screwdriver to press
the other.
b. While pressing tabs, push up on eyeball to
detach it.
Figure 28. Loosening the eyeball
4. Detach slip ring connector (Figure 29).
Figure 29. Detaching the eyeball