Intellex
®
Digital Video Management System Installation and Operating Instructions
13
Installing the Intellex Unit
MORE>>>
INSTALLING THE
INTELLEX UNIT
Select a location for the unit that is clean and dry and where
temperature and humidity extremes do not exceed the product
specifications (see
). Failure to do so can
result in equipment failure and loss of warranty protection.
Make sure the location has stable AC power for the unit. Protect
the unit against severe power fluctuations by installing surge
protection devices on all power cables.
Required Connections
Cameras In
CAUTION: Protect the unit against lightning. If a portion of a
cable is installed outside of a building, the entire
cable is vulnerable to lightning. Therefore, install
surge protection devices on all vulnerable cables.
CAUTION: If you set the termination switch at 75 ohms, you
MUST select “Hi-Z” in the Intellex Setup Options
screen. If you select “75 ohms” in the Intellex Setup
Options screen, you MUST use the “infinity” symbol
setting on the termination switch (consult
System
Setup, Setup Options Screen
).
Connect the video output of each camera or other composite
video source to its corresponding
Camera In
connector.
Monitor
The monitor displays live and recorded cameras, as well as
system configuration and status information. Connect the VGA
cable from an SVGA monitor to the
Monitor
connector.
Power Setting
CAUTION: Before connecting power, set the voltage switch
to the correct voltage (“115” or “230”).
Switch the power supply to the correct input voltage setting: 115
or 230 volts.
Power In
CAUTION: You may want to install power line conditioning
equipment to protect the unit against severe power
fluctuations.
CAUTION: Do not apply power until you have connected all
optional items. The Intellex unit will start operating
immediately once power is applied.
Connect the power cable to the unit.
Mouse
Connect the mouse (or other pointing device) to the
Mouse
connector.