American Dynamics ADACSNETD Скачать руководство пользователя страница 5

 

SENSORNET/MANCHESTER DISTRIBUTION PANEL 

8200-0712-01, REV. E 

INSTALLATION GUIDE 

5 of 5

 

Declarations 

Regulatory Compliance 

EMC............................................... 47 CFR, Part 15 
 ICES-003 
 EN 

55022 

Immunity................................................ EN50130-4 
Safety ....................................................UL 60950-1 
 CSA 

C22.2.60950-1 

 EN 

60950-1 

 IEC 

60950-1 

REGULATORY PRODUCT NAME:

 

TYPE: ADVDB 

FCC COMPLIANCE:

 This equipment complies with Part 15 

of the FCC rules for Class A digital devices when installed and 
used in accordance with the instruction manual. Following 
these rules provides reasonable protection against harmful 
interference from equipment operated in a commercial area. 
This equipment should not be installed in a residential area as 
it can radiate radio frequency energy that could interfere with 
radio communications, a situation the user would have to fix at 
their own expense. 

EQUIPMENT MODIFICATION CAUTION:

 Equipment 

changes or modifications not expressly approved by 
Sensormatic Electronics Corporation, the party responsible for 
FCC compliance, could void the user's authority to operate the 
equipment and could create a hazardous condition. 
See “About the Product” on page 1. 

Other Declarations 

Thank you for using American Dynamics products. We 
support our products through an extensive and worldwide 
network of dealers. The dealer, through whom you originally 
purchased this product, is your point of contact if you have a 
need for service or support. Our dealers are fully empowered 
to provide the very best in customer service and support. 
Dealers should contact American Dynamics at 
(800) 507-6268 or (561) 912-6259 or on the web at 
www.americandynamics.net. 

WARRANTY DISCLAIMER:

 Sensormatic Electronics 

Corporation makes no representation or warranty with respect 
to the contents hereof and specifically disclaims any implied 
warranties of merchantability or fitness for any particular 
purpose. 

NOTICE: 

The information in this manual was current when 

published. The manufacturer reserves the right to revise and 
improve its products. All specifications are therefore subject to 
change without notice. 

LIMITED RIGHTS NOTICE:

 For units of the Department 

of Defense, all documentation and manuals were developed at 
private expense and no part of it was developed using 
Government Funds. The restrictions governing the use and 
disclosure of technical data marked with this legend are set 
forth in the definition of “limited rights” in paragraph (a) (15) 
of the clause of DFARS 252.227.7013. Unpublished - rights 
reserved under the Copyright Laws of the United States. 

TRADEMARK NOTICE:

 

American Dynamics

 and 

Sensormatic

 are trademarks or registered trademarks of 

Sensormatic Electronics Corporation. Other product names 
mentioned herein may be trademarks or registered trademarks 
of Sensormatic or other companies. 

COPYRIGHT:

 Under copyright laws, the contents of this 

manual may not be copied, photocopied, reproduced, 
translated or reduced to any electronic medium or machine-
readable form, in whole or in part, without prior written 
consent of Sensormatic Electronics. 

WJM 01/2008 

 

www.americandynamics.net

Содержание ADACSNETD

Страница 1: ... Manchester multi point dome control communications and has 16 secondary device ports two connectors per port to accommodate home run dome wiring or multiple daisy chained connections to domes J boxes or other distribution panels Each of the ports has an LED that indicates data is being received Since Manchester communication is simplex one way communication received data is never present on the 1...

Страница 2: ...o ground Ensure metal to metal contact Configuration Considerations SW1 Switch Settings Pos 0 Setting 1 Setting 1 50µs Turnaround Time 1 50µs Turnaround Time 1 2 Manchester SensorNet 3 Not used Not used 4 Not used Not used 5 Not used Not used 6 Not used Not used 7 LED Test Mode 2 Normal Operation 8 State Machine Test Mode 3 Normal Operation Notes 1 Turnaround time Normally SW1 position 1 is set to...

Страница 3: ... equipment Input frequency 47 63Hz Allowable drop out 150ms Power connector pin assignments Pin Label Notes 1 and 3 12V 30V AC DC Connect 12 30V AC or DC power to these pins in any polarity 2 Ground Used for surge protection and data line shields Surge Protection SensorNet Manchester Ports Transient Voltage Suppressors TVS Break Down Voltage 7 6 9 3Vdc Peak Current 40A Capacitance 2000pf 1kHz Gas ...

Страница 4: ...hield not used Pin 1 S Black wire Pin 2 S White wire Pin 3 Ground Shield used Terminating Resistor 120Ω switch selectable 120Ω switch selectable Physical Layer RS 485 transformer isolated 2 wire RS 485 transformer isolated 2 wire Data Encoding FM 0 Manchester Link Layer Framing SDLC HDLC Proprietary Link Layer Channel Bi directional half duplex Simplex Collision Avoidance Polling by primary host c...

Страница 5: ...de the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose N...

Отзывы: