American Dynamics ADACSNETD Скачать руководство пользователя страница 2

 

SENSORNET/MANCHESTER DISTRIBUTION PANEL 

8200-0712-01, REV. E 

INSTALLATION GUIDE 

2 of 5

 

Installation 

Parts 

Install kit 0352-0331-01, used with the 0404-0383-01 
distribution panel. It includes grounding hardware. 

Part 

 

Qty 

Part Number 

User Guide, Video Sys Comm 
Protocols & Cable Networks 

8000-2573-19 

Con,p,Eur,3.5,22-16g,1x3p  

34 

2109-0510-03 

Con,p,Eur,.2c,28-12g,3p,orange  

2109-0254-02 

Cbl,3c,18g,16x30,pvc,cm  

16.50 

6002-0024-01 

Lbl,blnk,pap,therm,3.5x3,wh,rl  

2450-0008-01 

Scr,m,php,st,z,6-32x1/4 

2804-7106-06 

Wsh,int th,#6,st,z 

2845-6300 

Nut,hx,ss,6-32 

2836-0001-03 

Tm,spade,#6,22-16aw 

2141-0027-01 

Required Tools 

 Screwdriver 

 

Rack Installation 

1.  Position the distribution panel in the desired 

equipment rack location. 

2.  Using the appropriate screws, secure the 

distribution panel to the equipment rack. 

3.  For effective surge protection, ground the 

enclosure by rack mounting to a grounded rack 
or with a conductor from the enclosure to 
ground. Ensure metal-to-metal contact. 

Configuration Considerations 

SW1 Switch Settings 

Pos. 

0 Setting 

1 Setting 

50µs Turnaround 
Time

 (1)

 

> 50µs Turnaround 
Time

(1)

 

2 Manchester 

SensorNet 

Not used 

Not used 

Not used 

Not used 

Not used 

Not used 

Not used 

Not used 

LED Test Mode

(2)

 Normal 

Operation 

State Machine Test 
Mode

(3)

 

Normal Operation 

Notes: 

(1) 

Turnaround time: Normally, SW1 position 1 is 
set to ‘1.’ Setting SW1 position 1 to ‘0’ might be 
beneficial for some legacy domes at a short 
distance. 

(2) 

LED functional operation test mode: To test, set 
SW1 position 7 to ‘0.’ All LED indicators should 
turn on, except for the noise indicator. 

(3) 

State machine test mode: For engineering test 
only. Set SW1 position 8 to ‘1’. 

Termination Switches 

There are termination switches on each of the 16 
secondary device ports and the two Host ports. 
They are recessed so they cannot be accidentally 
tripped. Set a termination switch to terminate if it is 
located at the end of the line. Set the switch to not 
terminate if multiple wires connect to the port. This 
practice is similar to video termination rules in 
which terminators are only located at the end of a 
wire. 

Содержание ADACSNETD

Страница 1: ... Manchester multi point dome control communications and has 16 secondary device ports two connectors per port to accommodate home run dome wiring or multiple daisy chained connections to domes J boxes or other distribution panels Each of the ports has an LED that indicates data is being received Since Manchester communication is simplex one way communication received data is never present on the 1...

Страница 2: ...o ground Ensure metal to metal contact Configuration Considerations SW1 Switch Settings Pos 0 Setting 1 Setting 1 50µs Turnaround Time 1 50µs Turnaround Time 1 2 Manchester SensorNet 3 Not used Not used 4 Not used Not used 5 Not used Not used 6 Not used Not used 7 LED Test Mode 2 Normal Operation 8 State Machine Test Mode 3 Normal Operation Notes 1 Turnaround time Normally SW1 position 1 is set to...

Страница 3: ... equipment Input frequency 47 63Hz Allowable drop out 150ms Power connector pin assignments Pin Label Notes 1 and 3 12V 30V AC DC Connect 12 30V AC or DC power to these pins in any polarity 2 Ground Used for surge protection and data line shields Surge Protection SensorNet Manchester Ports Transient Voltage Suppressors TVS Break Down Voltage 7 6 9 3Vdc Peak Current 40A Capacitance 2000pf 1kHz Gas ...

Страница 4: ...hield not used Pin 1 S Black wire Pin 2 S White wire Pin 3 Ground Shield used Terminating Resistor 120Ω switch selectable 120Ω switch selectable Physical Layer RS 485 transformer isolated 2 wire RS 485 transformer isolated 2 wire Data Encoding FM 0 Manchester Link Layer Framing SDLC HDLC Proprietary Link Layer Channel Bi directional half duplex Simplex Collision Avoidance Polling by primary host c...

Страница 5: ...de the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose N...

Отзывы: