SENSORNET/MANCHESTER DISTRIBUTION PANEL
8200-0712-01, REV. E
INSTALLATION GUIDE
2 of 5
Installation
Parts
Install kit 0352-0331-01, used with the 0404-0383-01
distribution panel. It includes grounding hardware.
Part
Qty
Part Number
User Guide, Video Sys Comm
Protocols & Cable Networks
1
8000-2573-19
Con,p,Eur,3.5,22-16g,1x3p
34
2109-0510-03
Con,p,Eur,.2c,28-12g,3p,orange
1
2109-0254-02
Cbl,3c,18g,16x30,pvc,cm
16.50
6002-0024-01
Lbl,blnk,pap,therm,3.5x3,wh,rl
1
2450-0008-01
Scr,m,php,st,z,6-32x1/4
1
2804-7106-06
Wsh,int th,#6,st,z
1
2845-6300
Nut,hx,ss,6-32
1
2836-0001-03
Tm,spade,#6,22-16aw
2
2141-0027-01
Required Tools
•
Screwdriver
Rack Installation
1. Position the distribution panel in the desired
equipment rack location.
2. Using the appropriate screws, secure the
distribution panel to the equipment rack.
3. For effective surge protection, ground the
enclosure by rack mounting to a grounded rack
or with a conductor from the enclosure to
ground. Ensure metal-to-metal contact.
Configuration Considerations
SW1 Switch Settings
Pos.
0 Setting
1 Setting
1
50µs Turnaround
Time
(1)
> 50µs Turnaround
Time
(1)
2 Manchester
SensorNet
3
Not used
Not used
4
Not used
Not used
5
Not used
Not used
6
Not used
Not used
7
LED Test Mode
(2)
Normal
Operation
8
State Machine Test
Mode
(3)
Normal Operation
Notes:
(1)
Turnaround time: Normally, SW1 position 1 is
set to ‘1.’ Setting SW1 position 1 to ‘0’ might be
beneficial for some legacy domes at a short
distance.
(2)
LED functional operation test mode: To test, set
SW1 position 7 to ‘0.’ All LED indicators should
turn on, except for the noise indicator.
(3)
State machine test mode: For engineering test
only. Set SW1 position 8 to ‘1’.
Termination Switches
There are termination switches on each of the 16
secondary device ports and the two Host ports.
They are recessed so they cannot be accidentally
tripped. Set a termination switch to terminate if it is
located at the end of the line. Set the switch to not
terminate if multiple wires connect to the port. This
practice is similar to video termination rules in
which terminators are only located at the end of a
wire.