11
Power Connections
The 24VAC power lines enter the AD1273 through a 7-pin
Plug and Ramp connector (see Figure 9). The 7-pin Ramp
connector is mounted to the printed circuit board. The 7-pin
Plug mating connector is shipped with the AD1273 unit.
Assemble the 7-pin Plug connector by inserting the appropriate
24VAC power and ground lines into the corresponding slots
listed in Table 5 and tightening the hold-down screws.
Table 5 - 24VAC Power Lines to 7-Pin Plug Connector
• Pin 3 - 24VAC INPUT power signal
• Pin 4 - Dome chassis GROUND
• Pin 5 - 24VAC INPUT power signal
Wire Selection
Table 6 lists the wire gauge versus maximum distance allowed
between the AD1273 pan/tilt and the voltage source. Shielded
cable is recommended for most applications.
Note: Distance calculations are based on solid copper wire,
single common, and worst case current draw (i.e.,
diagonal pan/tilt operation).
Table 6 - Wire Gauge -vs- Distance
22AWG
20AWG
18AWG
16AWG
89ft
142ft
226ft
359ft
27.1m
43.3m
68.9m
109.4m
AD1273
CONNECTIONS
PCB Cover
A
A
A
A
A
AAA
AAA
A
A
AAAAA
AA
AA
AA
A
A
AA
A
A
AA
AA
1
2
3
4
5
6
7
7-Pin Plug Connector
1
2
3
4
5
6
7
24VAC
24VAC
Dome Chassis
Ground
7-Pin Ramp Connector
(Mounted to Circuit Board)
Figure 9 - Power Connections