American Dynamics AD100 Скачать руководство пользователя страница 7

8000-1796-01, Rev. B

Recorder Controller/Interface Installation Instructions     7

7.

 

When the transmission is finished, the 

Recorder

In...

 dialog box appears. Click “OK” to complete

the process.

8.

 

Repeat steps 1 through 7 for each non-default
recorder type being used in the system.

Note: Some users may prefer to perform the above
procedure in subdued lighting conditions for optimal
results.

Selecting the Module Type

1.

 

Click the appropriate Module # row in the Module
# column. The 

Select Module Type

 dialog box

appears.

2.

 

Select the 

Infra-Red

 option, and click the OK

button. A column of 16 outputs opens up below and
to the right of the selected module number.

Assigning Recorder Types to Outputs

Each recorder output must be assigned a recorder type
and a recorder number.

1.

 

To assign a recorder type to an output, click on the
appropriate selection in the left-most 

Recorder

Types

 column. The 

Recorder Library

 dialog box

appears.

2.

 

Press 

Cancel

.

3.

 

Click in the right-most Recorder Types column in
the row adjacent to the appropriate output number
(click and drag to assign the selected recorder type
to multiple outputs).

4.

 

Click on the arrow in the center of the initial RIU
window.

The selected recorder type will appear to the right of the
appropriate output(s).

Assigning Recorder Numbers to Outputs

1.

 

To assign a recorder number, click in the Recorder
# cell to the right of the appropriate output. The

Enter Recorder #

 dialog box appears.

2.

 

Use the up or down arrows to the right of the spin
box to select a recorder number. The number range
is 1 to 2048.

3.

 

Press the OK button. The number will appear in the
selected cell.

Saving the Map File / Data Transfer

1.

 

After selecting the recorder and module types, and
assigning recorder types and numbers to the
module outputs, select 

File/Save As

. The 

Recorder

Library

 dialog box appears. Name the map file

appropriately and click the 

Save

 button.

2.

 

Select 

Functions/Controller Setup/Transfer Setup

to AD100XA

. A progress bar will appear and

advance from zero to 100 percent, indicating that
the recorder interface data has been transferred
from the PC to the AD100XA.

Содержание AD100

Страница 1: ...ill also support recorder control Particular systems developed before AD1024 can support recorder control with appropriate upgrade equipment see the table on page 8 for details The AD Recorder Controller interface is available for both 120 VAC and 230 VAC applications Equipment Provided see Drawing 1 Page 3 Part Qty Part No Recorder Controller 120 VAC 1 AD100XA Recorder Controller 230 VAC 1 AD100X...

Страница 2: ...When used in concert with the recorder controller and utility software the IR interface module can control any recorder having IR capability Up to 2048 IR video recorders can be controlled on the network Each IR interface module is supplied with a transformer to power the unit RIU Recorder Interface Utility In order to implement the programming of the IR Interface Modules each Recorder Controller ...

Страница 3: ...quipment AD100 Series System Drawings Drawing 1 System Equipment AD100XA Front View This connector not used AD100XA Rear View AD100IR16 Front View AD100IR16 Rear View Modular Cable with DB9F DB9M Adaptors AD100IRE Emitter Cable 120 VAC Transformer 230 VAC Transformer Opening for Addressing Switch ...

Страница 4: ...called riu exe resides in the RIU folder 4 A new folder called Recorder Library resides in the C drive 5 Four VCR files are installed in the Recorder Library folder The filenames refer to four standard VCRs denoted by brand name and model number Launching the Application On the Windows desktop click the following sequence 1 Start 2 Programs 3 American Dynamics 4 Recorder Installation Utility The i...

Страница 5: ...ler Interface Installation Instructions 5 Drawing 2 Daisy Chain Configuration Drawing 3 AD100 Interface w PC Video Recorders AD100 Series System Drawings Drawing 2 Daisy Chain Configuration Drawing 3 AD100 Interface w PC Video Recorders ...

Страница 6: ...order Types If the system utilizes recorder types other than those provided as RIU default models the user must map the non default model s and learn the IR command set appropriate to the model s To map additional recorder types and learn the appropriate IR command sets perform the following steps 1 Select Functions Learn IR Commands The Recorder Library dialog box again appears see illustration u...

Страница 7: ...he right most Recorder Types column in the row adjacent to the appropriate output number click and drag to assign the selected recorder type to multiple outputs 4 Click on the arrow in the center of the initial RIU window The selected recorder type will appear to the right of the appropriate output s Assigning Recorder Numbers to Outputs 1 To assign a recorder number click in the Recorder cell to ...

Страница 8: ...the DB9F adaptor from the modular cable Connect the RJ 45 connector to the Peripheral Interface Port PIP of the AD1024 CPU Settings for the PIP are as follows Baud rate 9600 Data Bits 8 Stop Bits 1 Parity None 2 Using the AD2088 keyboard call up each of the system video recorder and test each of the recorder command functions see Drawing 4 page 9 Notes on Controller Setup Functions When the Functi...

Страница 9: ...8000 1796 01 Rev B Recorder Controller Interface Installation Instructions 9 Drawing 4 AD100 Interface w AD1024 System Drawing 4 AD100 Interface w AD1024 System ...

Страница 10: ... in Height 1 38 in AD100IR16 1 Length 5 50 in Width 3 25 in Height 1 38 in Environmental Specifications Operating Temp 5 C to 40 C 40 F to 104 F Humidity 95 non condensing Storage Temp 40 C to 70 C 40 F to 155 F Approvals UL UL listed transformer with device CSA CSA certified transformer provided w device CE CE marked transformer provided with device Warranty Disclaimer Sensormatic Electronics Cor...

Страница 11: ...ntonio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type AD100 Series Recorder Interface Modules Model Numbers AD100XA 1 AD100IR16 1 comply with the EMC Standards EN55022 Class B EN50082 1 and also comply with the following safety standard EN60950 Each module is provided with an external power supply Additional information These products herein comply with the req...

Страница 12: ...12 Recorder Controller Interface Installation Instructions 8000 1796 01 Rev B Sensormatic Video Systems Division 1 Blue Hill Plaza Pearl River New York 10965 914 624 7600 ...

Отзывы: