SETUP
Camera Block Assignments
The 2083/06 Code Translator must be set to identify the range
of camera numbers to be controlled by the unit. DIP switches,
both on the 2083/06 rear panel and internal to the unit, are used
to set the range of camera numbers to be controlled by each
connector group (1 - 4) on the rear panel. Within the range of
camera numbers selected, four separate cameras can be
connected and controlled via each connector group, for a total
of 16 cameras per 2083/06.
Four 8-position DIP switches (S1, S2, S3, and S4) are located
on the rear panel, as shown in Figure 1, page 1. The settings of
these DIP switches determine the camera number range
associated with the RS-422 connectors in each of the four
connector groups. Each group can process a separate block of
255, 64, 32, or 16 camera numbers, depending on the Camera
Mode set in DIP switch S5 (Table 1).
Two 8-position DIP switches (S5 and S6) are located on the
main 2083/06 PCB (see Figure 3). The switch positions of
DIP switch S5 are used for setup of the connectors Baud Rates
and the addressing Camera Mode. DIP switch S6 extends the
camera number range addressing of switches S1 - S4.
Refer to Table 3, pages 3 and 4, for the camera number range
settings of switches S1, S2, S3, S4, and S6.
Camera Mode
The S5 DIP switch is used to define the maximum range of
camera numbers that can be processed via each connector
group on the rear panel. This also determines the addressing
mode for the rear panel DIP switches S1 - S4 and internal
switch S6 (Table 3). The Camera Mode selected by switch S5
is the same for all four connector groups.
Table 1 shows the Camera Mode settings for switch S5. The
factory default settings are indicated in bold type.
Table 1 - S5, CAMERA MODE SETUP
Switch Positions (0=OFF, 1=ON)
Camera Number Mode
7
8
255
0
0
64
1
0
32
0
1
16
1
1
Baud Rate Selection
The S5 DIP switch configures the baud rates for the RS-422
terminal pins of the Pelco interface connectors (page 5). For
the Pelco Intercept Dome connections, set the RS-422 baud
rate to 2400.
Table 2 shows the baud rate settings for switch S5. The
factory default settings are indicated in bold type.
Table 2 - S5, BAUD RATE SETUP
Switch Positions (0=OFF, 1=ON)
Baud Rate
5
6
1200
0
0
2400
1
0
4800
0
1
9600
1
1
2
SETUP
S 5
S 6
FRONT
8
1
o f f
Figure 3 - Location of Internal DIP Switches
- CAUTION -
The following internal adjustments expose hazardous-
voltage components and allow access to dangerous
electric shock potentials. These adjustments should be
made only by qualified service personnel.