![American Dryer Corp. ML-82 III Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/american-dryer-corp/ml-82-iii/ml-82-iii_installation-manual_2923498013.webp)
113344 - 9
www.amdry.com
9
IMPORTANT: Dryer
must be
installed in a location/environment, which the ambient
temperature remains between 40º F (4.44º C) and 130º F (54.44º C).
B. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap and optional shipping box) from dryer.
IMPORTANT:
Dryer
must be
transported and handled in an upright position at
ALL
times.
The dryer can be moved to its final location with or without the skid attached. To unskid the dryer, locate and
remove the four (4) bolts securing the base of the dryer to the wooden skid. Two (2) are located at the rear base
(remove the back panel for access), and two (2) are located in the bottom of the lint chamber. To remove the
two (2) bolts located in the lint chamber area, remove lint drawer completely. (Refer to
page 37
for lint drawer
removal instructions.) Once the bolts are removed and the lint drawer is reinserted, slide the dryer off of the
skid.
With the skid removed, to make it easier to slide the dryer into its final position, slightly lower
ALL
four (4)
leveling legs, so that the dryer will slide on the legs instead of the base frame.
1. Inside the basket (tumbler) of this dryer is an exhaust transition piece that
must be
installed on the outlet of
the exhaust before any further venting is connected. To do this, follow the procedures listed below:
a. Remove the exhaust transition piece from the basket (tumbler) and place it on the exhaust outlet.
b. Using the screws provided, secure the exhaust transition piece to the dryer.
NOTE: It
is
recommended
that this joint be taped as well as
ALL
other duct joints to prevent
moisture and lint from escaping into the building.
WARNING
An exhaust duct transition piece is shipped inside of the dryer’s
tumbler and
must be
installed on the dryer’s exhaust duct, with
the hardware provided,
BEFORE
location venting is connected
to the dryer.
THIS EXHAUST DUCT TRANSITION PIECE
MUST BE INSTALLED FIRST!
Failure to observe this installation requirement may result in damage
to the dryer, create a
FIRE HAZARD
and will
VOID
the
manufacturer’s warranty.
012999JEV-GS/cj
P/N: 114092
2. Leveling Dryer
The dryer is equipped with four (4) leveling legs, one (1) at each
corner of the dryer base. Two (2) are located at the rear of the
dryer base, and two (2) are located in the lint chamber. To increase
bearing life and improve efficiency, the dryer
should be
tilted
slightly to the rear.
Содержание ML-82 III