37
F. GAS INFORMATION
It is your responsibility to have
ALL
plumbing connections made by a qualified professional to assure that the
gas plumbing installation is adequate and conforms with local and state regulations or codes. In the absence of
such codes,
ALL
plumbing connections, materials, and workmanship
must conform
to the applicable requirements
of the National Fuel Code ANSI Z223.1-LATEST EDITION or in Canada, CAN/CGA-B149.1-M91 (Natural
Gas) or CAN.CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing),
as well as local codes and ordinances and
must be
done by qualified professional.
IMPORTANT:
Failure to comply with these codes or ordinances, and/or the requirements
stipulated in this manual, can result in personal injury and improper operation of
the dryer.
The dryer and its individual shut-off valves
must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryer
must be
isolated from
the gas supply piping system by closing its individual manual shut-off valve during any pressure test of the gas
supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT:
Failure to isolate or disconnect the dryer from gas supply as noted can cause
irreparable damage to the gas valve which will VOID THE WARRANTY.
WARNING: FIRE or EXPLOSION COULD RESULT.
1. Gas Supply
The gas dryer installation
must meet
the American National Standard...National Fuel Gas Code ANSI Z223.1-
LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P.
Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances
and
must be
done by a qualified professional.
NOTE:
Undersized gas piping will result in ignition problems, slow drying, increased use of
energy, and can create a safety hazard.
The dryer
must be
connected to the type of heat/gas indicated on the dryer label affixed behind the right
control box door.
If this information does
not agree with the type of gas available, DO NOT operate the
dryer.
Contact the distributor who sold the dryer or the
ADC
factory.
IMPORTANT:
Any burner changes or conversions
must be
made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (609.6 meters), unless
elevation requirements of over 2,000 feet (609.6 meters) were specified at the time the dryer order was
placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet
(609.6 meters) are made by changing each burner orifice. If this conversion is necessary, contact the distributor
who sold the dryer or contact the
ADC
factory.