23
2. Electrical Service Specifications
* AWG Stranded Type Wire ... size wire as per National Electrical Code or local codes.
(Motor lead type wire is recommended).
IMPORTANT:
The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label
exactly
.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
ML-130 II Reversing, 3ø (GAS)
ML-130 II Reversing, 3ø (STEAM)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT
: 208 VAC AND 230/240 VAC
ARE NOT THE SAME
.
When ordering,
specify exact voltage
.
NOTES
: A. When fuses are used they
must be
dual element, time delay, current limiting, class RK1 or RK5
ONLY
.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY
. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers
must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
208
3ø
3
13.7
13.7
*
20
20
20
20
230/240
3ø
3
12.5
12.8
*
20
20
20
20
38
0-400
3ø
3/4
---
7.
3
*
---
15
---
15
416
3ø
3/4
---
7.
2
*
---
15
---
15
460
3ø
3/4
7.
2
---
*
15
---
15
---
480
3ø
3/4
7.
2
---
*
15
---
15
---
575
3ø
3
6.3
---
*
15
---
15
---