23
c. 3-Phase (3ø) Wiring Connections (Hookup) - For Reversing Models Only
The electrical connections on
ALL
3-phase (3ø) gas model dryers are made into the rear service box
located at the upper left area of the dryer. Electrical connections for electrically heated dryers are
made in the electric oven area located at the upper rear of the dryer.
NOTE: A CIRCUIT SERVICING EACH DRYER
MUST BE
PROVIDED
.
If local codes permit, power to a gas dryer can be made
by the use of a flexible U.L. listed power cord/pigtail (wire
size
must conform
to rating of dryer), or the dryer can
be hard wired directly to the service breaker panel. In
ALL
cases, a strain relief
must be
installed where the
wiring enters the dryer.
The only electrical input connections to the dryer are the
3-phase (3ø) power leads (L1, L2, L3, and sometimes
neutral) and ground. Single-phase (1ø) power for the
control circuit is done internally to the dryer. No single-
phase (1ø) input connection is required on a 3-phase (3ø)
dryer.
For gas model dryers manufactured for operation at 3-phase
(3ø), the electrical connections are made at the power
distribution block located in the service box at the rear, upper
left corner of the dryer. The ground connection is made to the
copper lug also provided in this box. To gain access to the
service box contactor, the service box cover
must be
removed.