1. Handling of Batteries

1.1 Do Not Short Circuit the Battery

Try to never short circuit the battery. It generates a very high 

current which could cause the battery to overheat which may 

result in electrolyte gel leakage, harmful fumes, or explosion. 

The LIR tabs may easily short-circuit by placing them on con-

ductive surface. A short circuit may lead to heat build up and 

damage of the battery. An appropriate circuitry with PCM is 

employed to protect accidental short circuit of the battery pack.
1.2 Mechanical shock

Droping the unit, impact hit, bending, etc. may cause failure or 

shortend life of the LIR battery.
3. Other

3.1 Battery connection

1). Direct soldering of wire leads or devices to the battery is 

strictly prohibited.
2). Lead tabs with pre-soldered wiring shall be spot welded to 

the batteries. Direct soldering may cause damage of compo-

nents, such as separator and insulator, by heat build up.
3.2 Prevention of short circuit within a battery pack

There is enough insulation layers between wiring and the bat-

teries to provide extra safety protection. The battery pack is 

constructed in a way that no short circuit will occur which may 

cause smoke or fire.
3.3 Do No Disassemble the Batteries

1). Never disassemble the batteries.

Doing this may cause a internal short circuit in the battery, 

which may lead to harmful fumes, fire, explosion, or other prob-

lems.
2). Electrolyte Gel is harmful

Electrolyte Gel should not leak from the LIR battery. Should the 

electrolyte gel come into contact with the skin or eyes, flush the 

area of contact immediately with fresh water and seek medical 

attention immediately.
3.4 Do Not Expose the Battery to Heat or Fire

Never incinerate or dispose of the batteries in fire. This may 

cause an explosion, which would be very dangerous.
3.5 Do Not Expose the Battery to water or liquids

Never soak/drop the batteries in liquids such as water, seawa-

ter, drinks such as soft drinks, juices, coffee or other.
3.6 Battery Replacement

For battery replacement please contact ADJ customer support 

(800) 322-6337.
3.7 Do Not use a damaged Battery

The battery could be damaged during shipping, caused by 

shock. Should the battery be found damaged, including dam-

ages to the plastic casing of the battery, deformation of the 

battery package, smelling of an electrolyte, or leakage of the 

electrolyte gel, or other, DO NOT use the battery. A battery with 

a odor of electrolyte or a gel leakage should be placed away 

from fire to avoid fire or explosion.
4. Battery Storage

When storing the battery, it should be stored at room tempera-

ture, with a charge of at least 50%. We recommend that during 

long periods of storage that the battery be charged every 6 

months. Doing this will prolong the life of the battery and will 

also make sure that the battery charge does not fall below the 

30% mark.
5. Other Chemical Reaction

Because batteries utilize a chemical reaction, battery per-

formance will deteriorate over time even if stored for a long 

period of time without being used. In addition, if the various 

usage conditions such as charge, discharge, ambient tempera-

ture, etc. are not maintained within the specified ranges, the 

  WiFLY Bar QA5                                   Battery Precautions

  WiFLY Bar QA5                                   Battery Precautions

Содержание WIFLY BAR QA5

Страница 1: ...you wish without the restrictions of power or DMX cabling The built in battery will keep charge for up to 6 hours full on from a full single charge This fixture can be used in a stand alone mode or connected in a Master Slave configuration This wash has five operating modes Sound Active mode Auto mode RGB mode Static Color mode and DMX control mode Customer Support ADJ Products LLC provides a cust...

Страница 2: ... the manufacturer See page 30 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the appliance ...

Страница 3: ...e LIR battery Should the electrolyte gel come into contact with the skin or eyes flush the area of contact immediately with fresh water and seek medical attention immediately 3 4 Do Not Expose the Battery to Heat or Fire Never incinerate or dispose of the batteries in fire This may cause an explosion which would be very dangerous 3 5 Do Not Expose the Battery to water or liquids Never soak drop th...

Страница 4: ...ixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The WiFLY Bar QA5 can be controlled via DMX 512 protocol...

Страница 5: ...le s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior WiFLY Bar QA5 Set Up DMX512 IN 3 PIN XLR POWER POWER POWER DMX512 DMX DMX COMMON 1 2 3 Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable to connect a...

Страница 6: ...you to control each individual fixture s traits with a standard DMX 512 controller WiFLY Bar QA5 Operating Instructions RGBA Dimmer Mode 1 Plug the fixture in and press the MODE button until 2 When r XXX is displayed you are in Red dimming mode Press the UP and DOWN buttons to adjust intensity 3 When G XXX is displayed you are in Green dimming mode Press the UP and DOWN buttons to adjust intensity...

Страница 7: ...nt the current DMX Channel Mode 4 Use the UP or DOWN buttons to scroll through the DMX Channel modes The Channel modes are listed below To run the 4 Channel Mode press the MODE button until Ch04 is displayed To run the 6 Channel Mode press the MODE button until Ch06 is displayed To run the 7 Channel Mode press the MODE button until Ch07 is displayed To run the 8 Channel Mode press the MODE button ...

Страница 8: ...municate up to 400 feet open line of sight NOTE The ADJ RFC control must be set to OFF to use this func tion 1 Turn on the WiFly function using the WiFly On Off switch and set the attenna to a upright position 2 Follow the instructions on page 14 to set the Wireless address The address must match the address set on the WiFly Transceiver 3 After you have set the WiFly address follow the DMX instruc...

Страница 9: ... In Built In Program mode Use the or to scroll through the built in programs Once you have found your desired program and you can press the SPEED button and then use the and buttons to adjust the program speed You can press the Flash Button to activate strobing and use the or to adjust the Flash rate Press the FLASH button again to enter Fade time and use the and buttons to adjust the fade speed F...

Страница 10: ...hannel Value Function 1 RED 0 255 0 100 2 GREEN 0 255 0 100 3 BLUE 0 255 0 100 4 AMBER 0 255 0 100 5 MASTER DIMMER 0 255 0 100 6 STROBING PROGRAM SPEED SOUND SENSITIVITY ADJUSTMENTS 0 15 NOTHING 16 255 STROBING SLOW FAST 0 255 PROGRAM SPEED SLOW FAST 0 255 SOUND SENSITIVITY LEAST MOST 7 DIMMING COLOR MACRO PROGRAM MODE SOUND ACTIVE 0 51 DIMMER MODE 52 102 COLOR MACRO MODE 103 204 PROGRAM MODE 205 ...

Страница 11: ...OGRAM 11 135 145 PROGRAM 12 146 156 PROGRAM 13 157 167 PROGRAM 14 168 178 PROGRAM 15 179 189 PROGRAM 16 190 200 PROGRAM 17 201 211 PROGRAM 18 212 222 PROGRAM 19 223 233 PROGRAM 20 234 244 PROGRAM 21 245 255 PROGRAM 22 WiFLY Bar QA5 8 Channels DMX Values Functions When Channel 8 is between the values of 234 255 Programs 21 22 Channel 3 will let you select a flow color and Channel 4 will let you sel...

Страница 12: ... 255 0 100 13 RED LED 4 0 255 0 100 14 GREEN LED 4 0 255 0 100 15 BLUE LED 4 0 255 0 100 16 AMBER LED 4 0 255 0 100 Channel Value Function 6 PROGRAMS CONT 226 235 PROGRAM 22 236 245 AUTO RUN 246 255 SOUND ACTIVE 7 PROGRAM SPEED SOUND SENSITIVE 0 255 PROGRAM SPEED SLOW FAST 0 255 SOUND SENSITIVITY LEAST SENSITIVE MOST SENSITIVE 8 STROBING 0 15 NOTHING 16 255 STROBING SLOW FAST 9 MASTER DIMMER 0 255...

Страница 13: ...lor30 161 165 0 38 86 0 Color7 46 50 255 0 255 0 Color31 166 170 0 142 208 0 Color8 51 55 255 0 0 255 Color32 171 175 52 148 209 0 Color9 56 60 0 255 255 0 Color33 176 180 1 134 201 0 Color10 61 65 0 255 0 255 Color34 181 185 0 145 212 0 Color11 66 70 0 0 255 255 Color35 186 190 0 121 192 0 Color12 71 75 255 255 255 0 Color36 191 195 0 129 184 0 Color13 76 80 255 255 0 255 Color37 196 200 0 83 115...

Страница 14: ... battery is charging or if the battery life is below 30 the digital display will flash NOTE After 20 seconds of inactivity the display will revert back to the battery life display Battery Recharge To recharge the battery plug the supplied AC cord into the AC input on the side of the unit and plug the other end into a matching power supply It takes about 5 5 hours to reach full charge The display w...

Страница 15: ...ter which way the inputs and outputs are connected Unit does not respond to sound 1 Quiet or high pitched sounds will not activate the unit 2 Make sure that Sound Active mode is activated WiFLY Bar QA5 Cleaning Due to fog residue smoke and dust cleaning the internal and exter nal optical lenses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to...

Страница 16: ...its products without any obligation to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by ADJ Products LLC in connection with this product including warranties of merchantability o...