background image

ADJ Products, LLC  -  www.adj.com  - Vortex 1200 User Manual Page 4

ADJ Products, LLC  -  www.adj.com  - Vortex 1200 User Manual Page 5

  Vortex 1200                                           Safety Precautions

•   To reduce the risk of electrical shock or fire, do not expose this unit  

   rain or moisture

•   Do not spill water or other liquids  into or on to your unit.

•   Be sure that the local power outlet match that of the required volt- 

   age for your unit.

•   Do not attempt to operate this unit if the power cord has been   

   frayed or broken. Do not attempt to remove or break off the ground 

   prong from the electrical cord. This prong is used to reduce the risk  

   of electrical shock and fire in case of an internal short.

•   Disconnect from main power before making any type of connection.

•   Do not remove the cover under any conditions. There are no user  

   serviceable parts inside.

•   Never operate this unit when it’s cover is removed.

•   Never plug this unit in to a dimmer pack

•   Always be sure to mount this unit in an area that will allow proper  

   ventilation. Allow about 6” (15cm) between this device and a wall.

•   Do not attempt to operate this unit, if it becomes damaged.

•   This unit is intended for indoor use only, use of this product out`  

   doors voids all warranties.

•   During long periods of non-use, disconnect the unit’s main power.

•   Always mount this unit in safe and stable matter.

•   Power-supply cords should be routed so that they are not likely to  

   be walked on or pinched by items placed upon or against them,  

   paying particular attention to the point they exit from the unit. 

• Cleaning -The fixture should be cleaned only as recommended by  

  t he manufacturer. See page 32 for cleaning details.

•   Heat -The appliance should be situated away from heat sources  

   such as radiators, heat registers, stoves, or other appliances (inclu-

   d ing amplifiers) that produce heat.

•   The fixture should  be serviced by qualified service personnel when:

    A. The power-supply cord or the plug has been damaged.

    B. Objects have fallen, or liquid has been spilled into the appliance.

    C. The appliance has been exposed to rain or water.

    D. The appliance does not appear to operate normally or exhibits a  

        marked change in performance.

The Vortex 1200 is fully operational in two different mounting posi-

tions, hanging upside-down from a ceiling or set on a flat level sur-

face. To avoid internal damage to the unit, never mount the unit on 

its side as illustrated above. Be sure this fixture is kept at least 0.5m 

away from any flammable materials (decoration etc.). Always use 

and install the supplied safety cable as a safety measure to prevent 

accidental damage and/or injury in the event the clamp fails (see next 

page). Never use the carrying handles for secondary attachment.

When installing the unit, the trussing or area of installation must be 

able to hold 10 times the weight without any deformation. When 

installing the unit must be secured with a secondary safety attach-

ment, e.g. and appropriate safety cable. Never stand directly below 

the unit when mounting, removing, or servicing the unit. 
Overhead mounting requires extensive experience, including calculat-

ing working load limits, installation material being used, and perodic 

safety inspection of all installation material and unit. If you lack these 

qualifications, do not attempt the installation yourself.
These installaiton should be checked by a skilled person once a year.

  Vortex 1200                                                       Installation

Содержание Vortex 1200

Страница 1: ...s or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages i...

Страница 2: ...is a great piece for nightclubs bars and stage productions This unit can be used as a stand alone unit or in a Master Slave configuration The unit has 3 operating modes show mode sound active and DMX...

Страница 3: ...urer See page 32 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat T...

Страница 4: ...knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Vortex 1200 can be controlled via DMX 512...

Страница 5: ...line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior DMX512 IN 3 PIN XLR UND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT PO...

Страница 6: ...Hold Blackout or Show will be displayed Choose an operating mode you would like the unit to start up in when either power is applied or the DMX signal is lost Blackout If the DMX signal is lost or pow...

Страница 7: ...tons to adjust the value Once you have made your adjust ment press ENTER 4 Repeat steps 2 3 until satisfied Vortex 1200 System Menu Vortex 1200 System Menu will automatically go into stand by mode Hol...

Страница 8: ...l now be displayed Press MENU to exit Fan Mode With this function you can control the fan operation 1 Press the MENU button until Fan Mode is displayed press ENTER 2 Either Auto Low or High will now b...

Страница 9: ...the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XL...

Страница 10: ...ION 8 15 MACRO 1 16 23 MACRO 2 24 31 MACRO 3 32 39 MACRO 4 40 47 MACRO 5 48 55 MACRO 6 56 63 MACRO 7 64 71 MACRO 8 72 79 MACRO 9 80 87 MACRO 10 88 95 MACRO 11 96 103 MACRO 12 104 111 MACRO 13 Vortex 1...

Страница 11: ...E RGBW CHANGE 100 109 NOTHING 110 119 EFFECT WHEEL MOTOR RESET 120 199 PAN TILT MOTOR RESET 200 209 ALL MOTOR RESET 210 249 NOTHING 250 255 SOUND ACTIVE Vortex 1200 14 Channel Mode Channel Value Funct...

Страница 12: ...20 199 PAN TILT MOTOR RESET 200 209 ALL MOTOR RESET 210 249 NOTHING 250 255 SOUND ACTIVE 15 DIMMER CURVES 0 20 STANDARD 21 40 STAGE 41 60 TV Vortex 1200 15 Channel Mode Channel Value Function 9 EFFECT...

Страница 13: ...ACRO 13 150 159 MACRO 14 160 169 MACRO 15 170 179 MACRO 16 180 189 MACRO 17 Vortex 1200 17 Channel Mode Channel Value Function 9 COLOR MACROS 190 199 MACRO 18 200 209 MACRO 19 210 219 MACRO 20 220 229...

Страница 14: ...alue Function 14 PAN TILT MACROS 48 55 MACRO 6 56 63 MACRO 7 64 71 MACRO 8 72 79 MACRO 9 80 87 MACRO 10 88 95 MACRO 11 96 103 MACRO 12 104 111 MACRO 13 112 119 MACRO 14 120 127 MACRO 15 128 135 MACRO...

Страница 15: ...J Products LLC www adj com Vortex 1200 User Manual Page 27 ADJ Products LLC www adj com Vortex 1200 User Manual Page 28 Channel Value Function 21 COLOR MACROS 140 149 MACRO 13 150 159 MACRO 14 160 169...

Страница 16: ...112 119 MACRO 14 120 127 MACRO 15 128 135 MACRO 16 136 143 MACRO 17 144 151 MACRO 18 152 159 MACRO 19 160 167 MACRO 20 168 175 MACRO 21 176 183 MACRO 22 184 191 MACRO 23 192 199 MACRO 24 200 207 MACR...

Страница 17: ...d are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are conne...

Страница 18: ...ction affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser b...

Отзывы: