background image

ADJ Products, LLC  -  www.adj.com  - Quad Phase HP Instruction Manual Page 13

ADJ Products, LLC  -  www.adj.com  - Quad Phase HP Instruction Manual Page 14

 Quad Phase HP   

                                      Operation

  together via the XLR connector on the rear of the units. Remem- 

  ber the Male XLR connector is the input and the Female XLR    

  connector is the output. The first unit in the chain (master) will use  

  the female XLR connector only - The last unit in the chain will use  

  the male XLR connector only. For longer cable runs we suggest a  

  terminator at the last fixture.
2.   On the Master unit find your desired show and set that show by  

  pressiing the ENTER button.

3.  On the slave units 

tap the MENU button until “SLND”  is dis-  

  played, select your desired slave mode and Press ENTER.
4.   The slave units will now follow the Master unit.
5.  The optional UC3 Controller (not included) may be used to con- 

  trol different functions including blackout.

  Quad Phase HP                                               UC3 Control

With  this  feature  you  can  connect  the  fixtures  to  one  another 

using the IEC input and output sockets. The quantity that can be 

connected is 5 fixtures maximum. After 5 fixtures you will need 

to use a new power outlet. They must be the same fixtures. DO 

NOT mix fixtures.

 Quad Phase HP                           Power Cord Daisy Chain

 Quad Phase HP   

 

                           DMX Traits

 Channel 

  Value 

 

         Function

       

1                0 - 255                  COLOR SELECTION

                         1 - 16                             COLOR 1

                       17 - 33                             COLOR 2

                       34 - 50                             COLOR 3

                       51 - 67                             COLOR 4

                       68 - 84                             COLOR 5

                       85 - 101                           COLOR 6

                     102 - 118                           COLOR 7

                     119 - 135                           COLOR 8

                     136 - 152                           COLOR 9

                     153 - 169                          COLOR 10

                     170 - 186                          COLOR 11

                     187 - 203                          COLOR 12

                     204 - 220                          COLOR 13

                     221 - 237                          COLOR 14

                     238 - 255                          COLOR 15
       2                                                    ROTATION
                         0 - 9                          NO ROTATION

                       10 - 120            CLOCKWISE FAST - SLOW                               

 

          121 - 134                      NO ROTATION

                     135 - 245              COUNTER-CLOCKWISE 

                                                            SLOW - FAST

                     246 - 249                      NO ROTATION

                     250 - 255                     SOUND ACTIVE
       3                                                     STROBING

                            0                                     OFF

                         1 - 255             STROBING SLOW - FAST
       4                                                 SHUTTER OPEN

                         0 - 15                                OFF 

                       16 - 255                            OPEN      

Blackout Blackout the unit

Function

1. Synchronous strobe.

2. Two light strobe.

3. Sound control.

Rotation speed (1-8).

Mode

Strobe(LED OFF)

Chase(LED ON)

Содержание Quad Phase HP

Страница 1: ...irst Introduction The Quad Phase HP is a four channel DMX intelligent LED moonflower fixture The fixture can operate in as a stand alone fixture or in a Master Slave configuration The Quad Phase HP ha...

Страница 2: ...the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Quad Phase HP Safety Precautions ADJ Pro...

Страница 3: ...Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchas...

Страница 4: ...Use Pin 4 Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion Quad Phase HP Set Up The unit should be mou...

Страница 5: ...he ENTER and then press and hold the MENU button for at least 3 seconds to confirm Quad Phase HP System Menu DNST This mode can be used as a precaution mode that in case the DMX signal is lost the ope...

Страница 6: ...ty 1 being the least sensitive and 100 being the most sensitive 4 The optional UC3 Controller not included may be used to con trol different functions including blackout Master Slave Operation Sound A...

Страница 7: ...ent functions including blackout Quad Phase HP UC3 Control With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 5...

Страница 8: ...nstruction Manual Page 16 Quad Phase HP ADJ RC1 Operation The ADJ RC1 infrared remote sold seperately has many differnet functions and gives you complete control of your Mega Tri 60 To control the you...

Страница 9: ...reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the...

Страница 10: ...Degree Duty Cycle None DMX Channels 4 Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days Auto Sensing Voltage This fixture contains a automatic volt age switch which...

Отзывы: