background image

ADJ Products, LLC  -  www.adj.com  - Quad Phase HP Instruction Manual Page 6

ADJ Products, LLC  -  www.adj.com  - Quad Phase HP Instruction Manual Page 5

Power Supply:

 The ADJ Quad Phase HP contains a automatic volt-

age switch, which will auto sense the voltage when it is plugged into 

the power source. With this switch there is no need to worry about the 

correct power voltage, this unit can be plugged in anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-

gle controller, as long as all fixtures and the controller are DMX com-

pliant. To ensure proper DMX data transmission, when using several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The  Quad  Phase  HP  can  be  controlled  via  DMX-512 

protocol. The Quad Phase HP is a four channel DMX unit. The DMX 

address is set electronically using the controls on the back panel of 

the unit. Your unit and your DMX controller require a approved DMX-

512 110 Ohm Data cable  for  data  input  and  data  output  (Figure  1). 

We recommend Accu-Cable DMX cables. If you are 

making your own cables, be sure to use standard 

110-120 Ohm shielded cable (This cable may be 

purchased at almost all professional sound and 

lighting stores). Your cables should be made with 

a male and female XLR connector on either end of 

the cable. Also remember that DMX cable must be 

daisy chained and cannot be split.

 Quad Phase HP                                                       Set Up

Figure 1

 Quad Phase HP   

 

                                 Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer runs of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Содержание Quad Phase HP

Страница 1: ...irst Introduction The Quad Phase HP is a four channel DMX intelligent LED moonflower fixture The fixture can operate in as a stand alone fixture or in a Master Slave configuration The Quad Phase HP ha...

Страница 2: ...the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Quad Phase HP Safety Precautions ADJ Pro...

Страница 3: ...Ohm Data cable for data input and data output Figure 1 We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchas...

Страница 4: ...Use Pin 4 Do Not Use Pin 3 Pin 2 Pin 1 Pin 3 Pin 2 Not Used Not Used Data True signal Data Compliment signal Ground Shield 3 Pin XLR to 5 Pin XLR Conversion Quad Phase HP Set Up The unit should be mou...

Страница 5: ...he ENTER and then press and hold the MENU button for at least 3 seconds to confirm Quad Phase HP System Menu DNST This mode can be used as a precaution mode that in case the DMX signal is lost the ope...

Страница 6: ...ty 1 being the least sensitive and 100 being the most sensitive 4 The optional UC3 Controller not included may be used to con trol different functions including blackout Master Slave Operation Sound A...

Страница 7: ...ent functions including blackout Quad Phase HP UC3 Control With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 5...

Страница 8: ...nstruction Manual Page 16 Quad Phase HP ADJ RC1 Operation The ADJ RC1 infrared remote sold seperately has many differnet functions and gives you complete control of your Mega Tri 60 To control the you...

Страница 9: ...reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts at the...

Страница 10: ...Degree Duty Cycle None DMX Channels 4 Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days Auto Sensing Voltage This fixture contains a automatic volt age switch which...

Отзывы: