chase until the function is turned off.
Changing the output signal level:
The unit is cabable of sending an
analog output signal of +/- 10, +/- 12 +/- 15 volts. Determine what
voltage your pack requires and change the output voltage if neccessary.
The unit’s defult output is +10 volts. To change the output level:
1. Disconnect the units main power.
2. Remove the four phillips screws on the top of the unit.
3. On the rear of the unit there is a two poistion toggle switch. Use
this switch to select either positive or negative output.
4. At the rear of the unit there is also a chennel dip swich. Use the dip
swich to select the voltage output. Follow the chart as followed:
1. For 10 volts flip dip switches 1 and 4 to the on position.
2. For 12 volts flip dip switches 2 and 4 to the on position.
3. For 15 volts flip dip switches 3 and 4 to the on position.
Specifications:
Power Input:
AC 120V~60Hz
Fuse:
F315mA 250V GMA
Weight:
1.3Kg/2.5Lbs
Dimensions:
483x125x42mm/ 19”x5”x1.75”
DMX to Analog:
Maximum of 72 channels
Analog Output:
+/- 10V, +/- 12V, +/- 15V
©
American DJ Supply
®
www-americandj.com Multi-Data/Pak™ Instruction Manual Page 8
©
American DJ Supply
®
www-americandj.com Multi-Data/Pak™ Instruction Manual Page 7