H2O DMX PRO
52 Degree Lens Install
The install of the 52 Degree lens
is a pretty easy process. Please
be very carefull when doing this
install.
Unscrew and remove the focus
lens. Using your thumb, gently
push the lens outward until it
“pops” out.
When the lens “pops” out, the pic-
ture to the left is what you should
see. Remove the lens and retainer
ring.
Flip the focus lens barrel over and
insert the 52 degree lens. Care-
fully insert the retainer ring. Please
do this very carefully. Make sure
retainer ring is in correctly, flesh
against the lens. Now you can
screw the focus lens back into the
H2O DMX PRO.
With this feature you can connect the fixtures to one another
using the IEC input and output sockets. The quantity that can be
connected is 5 fixtures maximum. After 5 fixtures you will need to
use a new power outlet. They must be the same fixtures. DO NOT
mix fixtures.
©
American DJ Supply
®
- www.americandj.com - H2O DMX PRO Instruction Manual Page 14
©
American DJ Supply
®
- www.americandj.com - H2O DMX PRO Instruction Manual Page 13
H2O DMX PRO Power Cord Daisy Chain
H2O DMX PRO
Fuse Replacement
Fuse Replacement:
Locate and remove the unit’s power cord. Once
the cord has been removed located the fuse holder located inside the
power socket. Insert a flat-head screw driver into the power socket and
gently pry out the fuse holder. Remove the bad fuse and replace with a
new one. The fuse holder has a built-in socket for a spare fuse be sure
not to confuse the spare fuse with active fuse.
Warning:
If after replacing the fuse you continue to blow fuses, STOP
using the unit. Contact customer support for further instructions. Con-
tinuing to use the unit may cause serious damage.
Trouble Shooting:
Listed below is a problem that you may encounter,
with a solution.
No light output from the unit;
1. Be sure the fuse has not blown. The fuse is located on the rear
panel inside the power socket. See Fuse Replacement.
H2O DMX PRO
Trouble Shooting
Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning the
internal and external lenses should be carried out periodically to opti-
mize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Clean the external optics with glass cleaner and a soft cloth every
20 days.
3. Always be sure to dry all parts completely before plugging the
unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (I.e. smoke, fog residue, dust, dew). In heavy use we recom-
mend cleaning on a monthly basis. Periodic cleaning will ensure lon-
gevity, and crisp beam output.
H2O DMX PRO
Cleaning