American DJ H2O DMX PRO Скачать руководство пользователя страница 3

©

American DJ Supply

®

  -  www.americandj.com  - H2O DMX PRO Instruction Manual Page 5

©

American DJ Supply

®

  -  www.americandj.com  - H2O DMX PRO Instruction Manual Page 6

P

ower Supply:

 The American DJ

®

 H2O DMX PRO contains a auto-

matic  voltage  switch,  which  will  auto  sense  the  voltage  when  it  is 
plugged into the power source. With this switch there is no need to 
worry  about  the  correct  power  voltage,  this  unit  can  be  plugged  in 
anywhere.  

DMX-512:

 

DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal).

 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant. To ensure proper DMX data transmission, when using several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The H2O DMX PRO is a three channel DMX unit. The DMX address is set 
on the top panel of the H2O DMX PRO. Your unit and your DMX con-
troller require a approved DMX-512 110 Ohm Data cable for data input 
and data output. We recommend Accu-Cable DMX cables. If you are 
making your own cables, be sure to use standard 
110-120 Ohm shielded cable (This cable may be 
purchased at almost all professional sound and 
lighting stores). Your cables should be made with 
a male and female XLR connector on either end 
of the cable. Also remember that DMX cable must 
be daisy chained and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  
fixtures may be implemented in a 3-pin DMX line. When inserting stan-
dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 
these adaptors are readily available at most electric stores. The chart 
below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  H2O DMX PRO  

 

                                        DMX Set Up

  H2O DMX PRO  

 

                                        DMX Set Up

Содержание H2O DMX PRO

Страница 1: ...stem to your dealer with out first contacting customer support Customer Support American DJ provides a toll free customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www americandj com for any comments or suggestions Service Hours are Monday through Friday 8 00 a m to 4 30 p...

Страница 2: ...o your unit Do not attempt to operate this unit if the power cord hasbeen frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power before making any type of connection Do not remove the cover under any conditions There are no user servic...

Страница 3: ...le must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior DMX512 IN 3 PI...

Страница 4: ...is not pressed and held within eight seconds the fixture will automatically confirm and lock the change into the system memory To exit without making any changes press the MENU button H2O DMX PRO System Menu Addr DMX Address Setting via control board 1 Press the MENU button until Addr is displayed press ENTER 2 X will now be displayed X represents the displayed address Press the UP or DOWN buttons...

Страница 5: ...tions If you would set your desired color rotation speed and dimmer press the ENTER button after each submenu is adjusted Example COLO is displayed press ENTER Make your adjustments using the UP or DOWN buttons until your desired color projected After you have found your desired color press ENTER Scroll to the next function adjust and press ENTER 4 After you have made your desired settings press a...

Страница 6: ...ON 3 COLOR 0 10 WHITE 11 21 WHITE ORANGE 22 32 ORANGE 33 43 ORANGE GREEN 44 54 GREEN 55 65 GREEN BLUE 66 76 BLUE 77 87 BLUE YELLOW 88 98 YELLOW 99 109 YELLOW PURPLE 110 120 PURPLE 121 127 PURPLE WHITE 128 186 CLOCKWISE COLOR ROTATION FAST SLOW 187 196 STOP 197 255 COUNTER CLOCKWISE ROTATION SLOW FAST H2O DMX PRO DMX Values Traits H2O DMX PRO Master Slave Configuration Master Slave Configuration Th...

Страница 7: ...ted the fuse holder located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse holder Remove the bad fuse and replace with a new one The fuse holder has a built in socket for a spare fuse be sure not to confuse the spare fuse with active fuse Warning If after replacing the fuse you continue to blow fuses STOP using the unit Contact customer su...

Страница 8: ... to include these changes in any products theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by American DJ Inc in connection with this product including warranties of merchantability or fitness are limited in duration to...

Отзывы: