            System Menu

Master-Slave Configuration:

 

This function will allows you to link units together to run in a Master-Slave 

mode. In Master-Slave operation one unit will act as the controlling unit 

and the others will react to the controlling units built-in programs. Any 

unit can act as a Master or as a Slave however, only one unit can be pro-

grammed to act as the “Master.” 
Master-Slave Connections and Settings:

1.   Daisy chain your units via the XLR connector on the rear of the unit.  

  Use standard XLR data cables to link your units together. Remember 

  that the Male XLR connector is the input and the Female XLR con- 

  nector is the ouput. The first unit in the chain (master) will use the  

  female XLR connector only. The last unit in the chain will use the   

  male XLR connector only. 

2.   Connect the first “Slave” unit to the “Master.”

3.   On the “Master” unit press the MENU button until “M.XXX” is dis- 

    played. “XXX” representing either ON or OFF. Use the UP or  

 

    DOWN button to change the setting to ON. Make sure the “Slave”  

    units are all set to “Master” Off. The “Slave” unit will now follow the  

    “Master”.

  Fog Fury 3000    

 

           Master-Slave Set Up

A.XXX -

 

DMX Address Setting

. (“XXX” represents the dis-

played DMX address.)
1. Press the either the MENU, UP, or DOWN buttons until 

“A.XXX” is displayed. “XXX” represents the current address that 

is displayed
2. Press the UP or DOWN buttons to change/find your desired 

address. 

TIMER MODE

These menu settings are for Timer mode. Make these setting 

before activating the Timer Mode.

u.XXX -

 This is the Volume setting (output intensity).

1. Press the either the MENU button until “u.XXX” is displayed. 
2. Press the UP or DOWN buttons to change the output inten-

sity. 5 is the lowest output while 100 is highest output.

I.XXX -

 This is the Interval setting (set time in between 

fog output).

1. Press the either the MENU button until “I.XXX” is displayed. 
2. Press the UP or DOWN buttons to change the output interval. 

3 seconds is the lowest time while 255 seconds is longest time 

between output.

d.XX -

 This is the Dispersion time setting (length of fog 

output).

1. Press the either the MENU button until “d.XX” is displayed. 
2. Press the UP or DOWN buttons to change the dispersion 

time. 1 second is the lowest time while 10 seconds is longest 

output time.

DMX Mode:

Operating  through  a  DMX  controller  gives  the  user  the  freedom  to 

create their own programs tailored to their own individual needs. This 

function also allows you to use your fixtures as spot lights. The Fog 

Fury 3000 has 3 DMX channels. See page 11 for the DMX traits.

1.  This function will allow you to control each individual fixture’s   

  traits with a standard DMX 512 controller.

2. 

To run your fixture in DMX mode press the MENU button until    

  “A.XXX” is displayed. “XXX” represents the current displayed ad-

  dress. Use the UP or DOWN buttons to select your desired DMX   

 address.

3.   Please see page 11 for DMX values and traits.

4.   After you have set your DMX address plug in the fixture via the  

    XLR connections to any standard DMX controller.

  Fog Fury 3000    

 

                          DMX Mode

Содержание Fog Fury 3000

Страница 1: ...after granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names...

Страница 2: ...lly or exhibits a marked change in performance Fog Fury 3000 Safety Precautions ADJ Products LLC www adj com Fog Fury 3000 Instruction Manual Page 3 Introduction Congratulations you have just purchase...

Страница 3: ...nd of the cable Also remember that DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on...

Страница 4: ...achine on a flat dry surface Locate the included bracket from the package and install it using the supplied hard ware to the side casing Note The bracket is an optional accesso ry and may not be used...

Страница 5: ...P or DOWN buttons to change find your desired address TIMER MODE These menu settings are for Timer mode Make these setting before activating the Timer Mode u XXX This is the Volume setting output inte...

Страница 6: ...ill cause pump failure and or clogging This is the largest cause of failure in fog and haze machines Only ADJ Fog Juice is recom mended and not all fog juice is created equal Remote Operation Start by...