manualshive.com logo in svg
background image

ADJ Products, LLC  -  www.adj.com  - Fog Fury 3000 Instruction Manual Page 4

ADJ Products, LLC  -  www.adj.com  - Fog Fury 3000 Instruction Manual Page 5

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your ADJ Fog Fury 

3000. The ADJ Fog Fury 3000 is available in a 120v and 230v version. 

Because line voltage may vary from venue to venue, you should be 

sure your unit voltage matches the wall outlet voltage before attempt-

ing to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Fog Fury 3000 can be controlled via DMX-512 protocol. The Fog Fury 

3000 has 3 DMX channels. The DMX address is set on the back panel. 

Your unit and your DMX controller require a standard 3-pin XLR connec-

tor for data input and data output (Figure 1). We rec-

ommend Accu-Cable DMX cables. If you are making 

your own cables, be sure to use standard 110-120 

Ohm shielded cable (This cable may be purchased 

at almost all pro lighting stores). Your cables should 

be made with a male and female XLR connector on 

either end of the cable. Also remember that DMX 

cable must be daisy chained and cannot be split.

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs  of cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin DMX-

512 data cables for DATA transmission in place of 3-pin. 5-pin DMX  

fixtures may be implemented in a 3-pin DMX line. When inserting stan-

dard 5-pin data cables in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Fog Fury 3000    

                          DMX Information

  Fog Fury 3000    

                          DMX Information

Содержание Fog Fury 3000

Страница 1: ...after granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ADJ Products LLC brands and product names...

Страница 2: ...lly or exhibits a marked change in performance Fog Fury 3000 Safety Precautions ADJ Products LLC www adj com Fog Fury 3000 Instruction Manual Page 3 Introduction Congratulations you have just purchase...

Страница 3: ...nd of the cable Also remember that DMX cable must be daisy chained and cannot be split Figure 1 Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on...

Страница 4: ...achine on a flat dry surface Locate the included bracket from the package and install it using the supplied hard ware to the side casing Note The bracket is an optional accesso ry and may not be used...

Страница 5: ...P or DOWN buttons to change find your desired address TIMER MODE These menu settings are for Timer mode Make these setting before activating the Timer Mode u XXX This is the Volume setting output inte...

Страница 6: ...ill cause pump failure and or clogging This is the largest cause of failure in fog and haze machines Only ADJ Fog Juice is recom mended and not all fog juice is created equal Remote Operation Start by...

Страница 7: ...bility or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this p...

Страница 8: ...e DMX CHANNELS 3 DMX Channels DUTY CYCLE Not to exceed 6 hours turned on Voltage is preset at the factory and may not be changed Fog Fury 3000 Specifications ADJ Products LLC 6122 S Eastern Ave Los An...

Отзывы: