American DJ DJ Scan/RG Скачать руководство пользователя страница 2

©

American DJ Supply

®

  -  www

.americandj.com  - DJ Scan/RG™ Instruction Manual Page 4

©

American DJ Supply

®

  -  www

.americandj.com  - DJ Scan/RG™ Instruction Manual Page 3

  DJ Scan/RG™  

 

 

 

 

  Quick Star

t

The

 DJ

 Scan/RG™

 features

 a
 bright

 150

 watt/500

 hour

 lamp

 life

 

halogen bulb with a separate gobo and color wheel. 

The color wheel 

features seven brilliant colors plus white and the gobo wheel features 

6 gobos plus a large and small spot. 

This fixture incorporates the use 

of high quality stepper motors for a more accurate mirror movement. 

Mirror

 movement

 allows

 for

 a
 full

 90

 degree

 tilt

 (vertical)

 and

 a
 45

 

degree

 pan

 (horizontal).

 An
 internal

 built

 in
 microphone

 allows

 the

 

fixtures to run in Stand 

Alone mode so there is no need for an external 

controller

The DJ Scan/RG™ may also be set-up to run in a Master-

Slave mode when used in multiples, up to four units. When used in the 

Master-Slave mode, the unit will chase to several internal programs. 

The DJ Scan/RG™ can also be controlled via a standard DMX control-

ler
 such

 as

 the

 American

 DJ

®

 Show

 Designer

,™
 or
 the

 American

 

DJ

®

 DMX

 Operator

,™
 giving

 the

 user

 independent

 control

 over

 the

 

gobo and color wheel as well as the mirrors pan and tilt movements.

Note:

 The built in programs in the DJ Scan/RG™ are so good you may 

never need a DMX controller

.

• 

 ZB-JCR/H5 15V/150W

, 500 Hour Lamp.

• 

 DMX-512 Compatible.

• 

 Stepper motors for smooth movements.

• 

 7 colors plus white.

• 

 7 Gobos plus spot.

• 

 4 Rotating Gobos, 4 Fixed Gobos.

• 

 4 Replaceable Gobos (26mm diameter - 22mm viewable)

• 

 Master/Slave Operation

• 

 Sound Active.

• 

 Optional MINI/C controller

, for blackout control.

  DJ Scan/RG™  

 

 

 

 

      Featur

es

Master/Slave Quick Start Stand 

Alone Mode

Connect

 up

 to
 four

 units

 together

 via

 XLR

 cables.

 The

 master

 unit

 

will

 run

 the

 slaves

 to
 the

 masters

 built

 in
 programs

 and

 internal

 

microphone. Plug in all units. When the DJ Scan/RG™ is first turned 

on, it will run through an internal self test where it resets all motors to 

their zero position. 

After the self test the units will react to sound, and 

chase to the several built in programs.

•  

Do not spill water or other liquids  into or on to your unit.

•  

Be sure that the local power outlet match that of the required voltage 

  

for your unit.

•  

Do not attempt to operate this unit if the power cord has been frayed 

  

or broken. Please route your power cord out of the way of foot traffi

 c.

•  

Do not attempt to remove or break of

f the ground prong from 

  

the electrical cord. 

This prong is used to reduce the risk of electrical 

  

shock and fi

 re in case of an internal short.

•  

Disconnect 

from main power before making any type of connection.

•   

Do not remove the top cover under any conditions. 

There are no 

  

user serviceable parts inside.

•  

Never plug this unit in to a dimmer pack

•  

Always be sure to mount this unit in an area that will allow proper 

  

ventilation. 

Allow about 6” (15cm) between this device and a wall.

•  

Do not attempt to operate this 

unit, 

if 

it 

becomes damaged in any 

way.

•  

Never operate this unit when it’

s cover is removed.

•  

To
 reduce the risk of electrical shock or fi

 re, do not expose this unit 

  

rain or moisture

•  

This unit is intended for indoor use only

, use of this product outdoors 

  

voids all warranties.

•  

During long periods of non-use, disconnect the unit’

s main power

.

•  

Always mount this unit in safe and stable matter

.

•  

Power Cord Protection - Power cords should be routed so they are

  

 not likely to be walked on or pinched by items placed upon or against 

  

them,

 paying

 particular

 attention

 to
 cords

 at
 plugs,

 convenience

 

  

receptacles, and the point where they exit from the unit.

• Cleaning -The fixture should be cleaned only as recommended by 

  

the manufacturer

.

•  

Heat

 -The

 unit

 should

 be

 situated

 away

 from

 heat

 sources

 such

 

  

as
 radiators,

 heat

 registers,

 stoves,

 or
 other

 appliances

 (including

 

  

amplifiers) that produce heat.

•  

The fixture should  be serviced by qualified service personnel when:

  
 A. 
The power-supply cord or the plug has been damaged.

  
 B. Objects have fallen, or liquid has been spilled into the appliance.

  
 C. 
The appliance has been exposed to rain or water

.

  
 D.
 The

 fixture

 does

 not

 appear

 to
 operate

 normally

 or
 exhibits

 a
 

  
  

  

 marked change in performance.

  DJ Scan/RG™  

 

 

       Safety Pr

ecautions

Содержание DJ Scan/RG

Страница 1: ...t www americandj com for any comments or suggestions Toll free customer service hours are Monday through Friday 9 00 a m to 5 30 p m Pacifi c Standard Time Voice 800 322 6337 Fax 323 582 2610 E mail support americandj com Warning To prevent or reduce the risk of electrical shock or fi re do not expose this unit to rain or moisture Caution There are no user serviceable parts inside this unit Do not...

Страница 2: ...e units will react to sound and chase to the several built in programs Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required voltage for your unit Do not attempt to operate this unit if the power cord has been frayed or broken Please route your power cord out of the way of foot traffi c Do not attempt to remove or break off the g...

Страница 3: ...uld cause a short circuit and erratic behavior 1 2 3 1 2 3 DMX DMX COMMON DMX512 IN CONNECTOR 3 PIN DMX512 OUT CONTROLLER CONNECTOR 3 PIN American DJ Supply www americandj com DJ Scan RG Instruction Manual Page 5 DJ Scan RG Set Up Figure 2 DJ Scan RG Set Up American DJ Supply www americandj com DJ Scan RG Instruction Manual Page 6 Notice Be sure to follow fi gures two and three when making your ow...

Страница 4: ...ard DMX controller Follow the set up specifications that come with the controller DJ Scan RG Operating Instructions DJ Scan RG Operating Instructions American DJ Supply www americandj com DJ Scan RG Instruction Manual Page 8 American DJ Supply www americandj com DJ Scan RG Instruction Manual Page 7 Operating Modes You can use the DJ Scan RG in three ways Stand alone mode The unit will react to sou...

Страница 5: ...ways disconnect the main power before attempting to replace the lamp 1 Be sure to follow the proper procedures when handling halogen bulbs 2 Lamp replacement has been made simple by incorporating the use of a removable lamp tray and thumb screws 3 Loosen the thumb screw on rear cover 4 Remove the tray 5 Remove and replace the bulb 6 Reassemble Remember to always replace with the exact same type la...

Страница 6: ...n cable Unit does not respond to sound 1 Check to see if the unit is receiving DMX the green LED should be off 2 Tapping the microphone should cause the LED to flash quiet or high pitched sounds will not activate the unit If the red LED does not flash to sound there may be an internal problem 3 Be sure the audio sensitivity knob is turn in the full clockwise position maximum sensitivity Unit black...

Страница 7: ...192 223 GOBO 8 224 255 GOBO 4 96 127 GOBO 1 0 31 GOBO 3 64 95 GOBO 2 32 63 GOBO 5 128 159 GOBO 6 160 191 BLACKOUT 0 28 PURPLE 232 255 PINK 203 231 ORANGE 174 202 YELLOW 145 173 GREEN 116 144 BLUE 87 115 RED 58 86 WHITE 29 67 0 0 0 0 45 255 45 128 90 255 23 128 ROTATING ROTATING ROTATING ROTATING DJ Scan RG Focusing 1 To focus a DJ Scan RG it is best to first turn down the music sensitivity knob to...

Страница 8: ...e American DJ factory unless prior written authorization was issued to purchaser by Ameri can DJ if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specifi ed above American DJ will replace defec tive parts at its expense and ...

Отзывы: