American Dish Service ASQ II Скачать руководство пользователя страница 9

9

 

 

Copyright

 

ADS

 

Installation

 

ASQ

 

II,

 

Rev

 

1.0

 

11/16/2017

 

 

Any

 

modifications

 

to

 

the

 

chemical

 

delivery

 

system

 

for

 

smaller

 

containers

 

must

 

include

 

Closed

 

Loop

 

Chemical

 

Containers

 

(spill

 

proof

 

bottles)

 

in

 

a

 

secured

 

racking

 

system.

  

It

 

is

 

the

 

responsibility

 

of

 

the

 

user

 

of

 

the

 

machine

 

to

 

purchase

 

chemicals

 

in

 

spill

 

proof

 

containers.

  

FAILURE

 

CAN

 

RESULT

 

IN

 

SERIOUS

 

INJURY.

  

Never

 

place

 

chemicals

 

in

 

open

 

containers

 

or

 

containers

 

that

 

can

 

be

 

easily

 

tipped

 

over

 

when

 

moving

 

or

 

changing

 

product.

  

Failure

 

to

 

do

 

so

 

will

 

void

 

your

 

ADS

 

warranty.

 

CHEMICAL

 

ADJUSTMENT—Chemical

 

dispensing

 

is

 

controlled

 

by

 

a

 

mechanical

 

cam

 

timer.

 

All

 

chemical

 

products

 

must

 

be

 

adjusted

 

for

 

the

 

product’s

 

concentration

 

and

 

local

 

water

 

conditions.

 

It

 

will

 

be

 

necessary

 

to

 

adjust

 

initial

 

factory

 

settings

 

(See

 

below

 

for

 

Cam

 

Timer

 

Adjustment

 

Section).

 

Water

 

softeners

 

should

 

be

 

added

 

to

 

correct

 

hard

 

water

 

conditions.

 

Hard

 

water

 

is

 

often

 

treated

 

with

 

more

 

expensive

 

ware

washing

 

chemicals,

 

but

 

it

 

is

 

more

 

effective

 

and

 

less

 

destructive

 

to

 

the

 

metal

 

to

 

soften

 

the

 

water

 

before

 

it

 

comes

 

to

 

the

 

machine.

 

 

VISUAL

 

CHEMICAL

 

INDICATOR—

 

ASQII

 

Chemical

 

Flow

 

Indicator

 

 

According

 

to

 

NSF/ANSI

 

3,

 

section

 

5.19.3

 

and

 

5.19.5

 

“This

 

machine

 

must

 

be

 

operated

 

with

 

an

 

automatic

 

detergent

 

feeder

 

and,

 

if

 

applicable,

 

an

 

automatic

 

chemical

 

sanitizer

 

feeder,

 

including

 

a

 

visual

 

means

 

to

 

verify

 

that

 

detergents

 

and

 

sanitizers

 

are

 

delivered

 

or

 

a

 

visual

 

or

 

audible

 

alarm

 

to

 

signal

 

if

 

detergents

 

and

 

sanitizers

 

are

 

not

 

available

 

for

 

delivery

 

to

 

the

 

respective

 

washing

 

and

 

sanitizing

 

systems.

  

Please

 

see

 

instructions

 

for

 

electrical

 

and

 

plumbing

 

connections

 

located

 

in

 

this

 

manual

 

and

 

in

 

the

 

feeder

 

equipment

 

manual.”

 

‐‐

a

 

visual

 

means

 

to

 

verify

 

that

 

detergents

 

and

 

sanitizers

 

are

 

delivered;

 

or

 

a

 

visual

 

or

 

audible

 

alarm

 

to

 

signal

 

if

 

detergents

 

and

 

sanitizers

 

are

 

not

 

being

 

delivered

 

to

 

the

 

respective

 

washing

 

and

 

sanitizing

 

systems.

 

For

 

ADS

 

family

 

models

 

of

 

ET

AF

 

and

 

the

 

model

 

ASQ,

 

the

 

chemical

 

Flow

 

Indicator

 

(084

6403)

 

is

 

the

 

visual

 

means

 

to

 

indicate

 

liquid

 

is

 

flowing

 

in

 

the

 

feeder

 

system

 

for

 

detergent

 

and

 

sanitizer.

  

In

 

each

 

of

 

the

 

tubes

 

machined

 

through

 

the

 

clear

 

plastic

 

housing,

 

there

 

is

 

a

 

black

 

colored

 

marble

 

(099

1008).

  

Squeeze

 

tube

 

material

 

(092

2000)

 

is

 

inserted

 

in

 

both

 

upper

 

and

 

lower

 

tube

 

openings.

  

These

 

tubes

 

are

 

pushed

 

into

 

the

 

holes

 

of

 

the

 

housing

 

and

 

held

 

in

 

place

 

by

 

tension

 

of

 

the

 

tube

 

wall

 

against

 

the

 

housing’s

 

inner

 

surface.

  

When

 

inserting

 

the

 

squeeze

 

tubes

 

into

 

the

 

housing,

 

lubrication

 

using

 

dish

 

soap

 

is

 

helpful.

 

When

 

the

 

top

 

tube

 

of

 

the

 

indicator

 

is

 

connected

 

to

 

the

 

inlet

 

side

 

of

 

the

 

chemical

 

peristaltic

 

pump,

 

liquid

 

is

 

drawn

 

up

 

through

 

the

 

supply

 

tube

 

of

 

the

 

chemical

 

bucket.

  

The

 

liquid

 

is

 

drawn

 

into

 

the

 

bottom

 

of

 

the

 

Flow

 

Indicator

 

housing

 

and

 

lifts

 

the

 

black

 

indicator

 

marble

 

upward

 

in

 

the

 

visual

 

chamber.

  

This

 

movement

 

shows

 

flow

 

of

 

the

 

liquid

 

in

 

the

 

tube.

  

The

 

tube

 

with

 

red

 

colored

 

liquid

 

will

 

indicate

 

detergent

 

flowing,

 

the

 

tube

 

with

 

clear

 

liquid

 

will

 

indicate

 

sanitizer

 

(chlorine)

 

flowing.

  

Содержание ASQ II

Страница 1: ...cense P3 0111 306 If you have questions call 800 922 2178 or visit our website at www AmericanDish com The electrical power supplied to this machine is an imminent hazard that could result in severe b...

Страница 2: ...a qualified professional who will ensure that the equipment is installed in accordance with all applicable Codes Ordinances and Safety requirements Failure to follow the installation instructions coul...

Страница 3: ...chens All 15 and 20A 125V receptacles installed in kitchens even those that do not supply the countertop surface must be GFCI protected 8 This equipment is considered an item of heavy use It is not ra...

Страница 4: ...ank float wire sump heater attached Wash motor contactor next to rack counter THE SUSTAINER HEATER is rated 350 Watts at 120v and will draw approximately 3 amps It is not designed to provide operation...

Страница 5: ...S Follow all local plumbing and mechanical codes IMC 2012 section 507 2 2 requires Type II hoods for all commercial ware washers except where the heat and moisture loads are incorporated into the buil...

Страница 6: ...xible braded hose should not be used to connect the glasswasher The ID of the plastic liner for this type hose restricts flow The minimum size for water connection is pipe SINK FAUCET MIXING HEAD prob...

Страница 7: ...ust wear approved safety eye wear before connecting chemicals Read the chemical manufacturer s SDS MSDS sheets Chemicals can damage or corrode plumbing and stainless parts of the dishmachine Do not ru...

Страница 8: ...local health requirements however the increased chlorine will result in higher corrosion of metal parts Purpose built ware washing dispensers are needed to properly meter chemicals for wash and rinse...

Страница 9: ...a visual or audible alarm to signal if detergents and sanitizers are not available for delivery to the respective washing and sanitizing systems Please see instructions for electrical and plumbing co...

Страница 10: ...wo lower cam segments can form a notch in the perimeter see photo below right Above each cam is a timer switch with a metal finger that rides along the outer edge of the cam When the finger drops into...

Страница 11: ...water through the drain before the drain period ends It is at this point that the H2O FILL cam should be adjusted so the water solenoid turns the fill water on That function is controlled by the adjus...

Страница 12: ...for leaks Tighten any connections if needed 6 To operate turn on the main power circuit breaker and turn the glasswasher master switch to the ON position by turning it a quarter turn to the right 7 B...

Страница 13: ...t lever the carousel easily rotates and locks into the next position The carousel rotation can turn either way While one section of the carousel is being washed the operator can unload the cleaned gla...

Страница 14: ...e carousel drum by lifting up 1 1 2 until the carousel has cleared the pivot pin then pull it out and towards the front The pivot pin is attached to the top center of the cabinet Once the hood top and...

Страница 15: ...and IMPELLERS Drain Pump 063 2900 Motor Replacement and ASQ Wash Pump 063 3000 Motor Replacement ADS tool kit 088 1092 to replace seals for 092 2005 drain pump and 092 2006 wash pump After removing th...

Страница 16: ...g the impeller to the shaft Take the spring and cap out remove the 4 nuts and washers holding the housing to the motor Lift the pump housing off the motor from the back of the housing push the ceramic...

Страница 17: ...unt of dish soap With tool 088 1092 press the ceramic firmly to the bottom of the housing Turn the housing over check that seal and boot are fully seated in housing place protective shield over the th...

Страница 18: ...be the protective shield covering the threads slide the seal on the shaft use open side of the tool Carefully press the seal down the shaft until seated against the white ceramic portion of the seal D...

Страница 19: ...ust be aligned with impeller Note the impeller has a D cut hole which aligns with the motor shaft flat Place one drop of Loctite on shaft threads Brace impeller with a screwdriver and fasten locknut 0...

Страница 20: ...e wash pump 063 3000 for the ASQ is serviced in the same procedure steps as the drain pump with the exception of being larger in size and motor horsepower The part number for the seal installing tool...

Страница 21: ...21 Copyright ADS Installation ASQ II Rev 1 0 11 16 2017...