SERVICE PARTS LIST:

  

DH-100V Dehumidifier

 

 

ITEM  

PART NO. 

QTY. 

DESCRIPTION

 

 
 1 

4021818 

Accumulator 

 2 

AL99005 

Air Filter, Pleated, 2” x 16” x 20” 

 3 

4021468 

Air Filter, Foam Element 

 4 

4022037 

Blower w/ Capacitor (Fasco 7090-1874) 

 5 

4021589 

Capillary Tubes, .050" ID x 28" long 

 6 

4023474 

Compressor, Panasonic (2R12S3R126A-6A) 

 7 

4022144 

Compressor Overload (TI # MRA98706-673) (not shown) 

 8 

4017318 

Compressor Run Capacitor for Panasonic, 35 MFD, 370V 

 

4017799 

Compressor Run Capacitor for Tecumseh, 25 MFD, 440V 

 9 

4021396 

Condenser Coil 

10 

4021409 

Cord & Wire Harness 

11 4021470 

1  Defrost 

Thermostat 

 

4021648 

Defrost Thermostat Mounting Clip (item 11) 

12 4021395 

1  Evaporator 

Coil 

13 4020955 

1  Filter/Drier 

14 

4021626 

Hose, Drain, .56"ID x 8' 

15 4021469 

1  Humidity 

Controller 

16 

4021495 

Knob, Humidity Controller 

17 

4020554 

Switch, SPDT, for Fan 

18 

4021471 

Wheel, 2", Plastic 

19 

4021507 

Wiring Diagram (on Cover) (not shown) 

20 

4021453 

Optional Ducting Kit (for Inlet & Outlet) (not shown) 

21 

4020623 

Optional Outlet Collar (for Ducting Outlet only) (not shown) 

 
 

 

Figure 3 

Содержание DH-100V

Страница 1: ...to obtain maximum benefit from your DH 100V dehumidifier 1 Specifications Model DH 100V Dehumidifier Electrical 110 120 VAC 6 8 Amps grounded Capacity 100 pints day 80 F 60 RH Operating Temp Range 53 F min 105 F max Air Flow 255 CFM without external ducting 170 CFM 0 15 in wg external static Refrigerant Charge 1 lbs 14oz R 22 Optional Duct connections 8 round inlet outlet Size w o duct collars 20 ...

Страница 2: ...ied air into the room in which it s located An adequate airflow path must exist between the two rooms for this method to work well An additional humidity control may need to be mounted in the humid area and wired to the DH 100V to accurately maintain the desired humidity Local electrical codes must be followed when wiring the control 2 2 Electrical Requirements The DH 100V plugs into a common grou...

Страница 3: ...onger to reduce the area s RH to the setting The ALDES DHV 100V unit and refrigerant based dehumidifiers in general will reduce a warm space s RH to a lower level than that of a cool space It is therefore pointless to set the humidity control to excessively low levels in cool rooms doing so will result in long periods of ineffective dehumidifier run time Quality humidity meters are available from ...

Страница 4: ...ture across the entire coil from inlet to outlet The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil The accumulator prevents any liquid refrigerant from reaching the compressor The compressor evacuates the cool refrigerant gas from the accumulator and compresses it to a high pressure and temperature to repeat the process 5 3 Troubleshooting No dehumid...

Страница 5: ...mpressor circuit Test each component for continuity see the appropriate section if a defect is suspected 3 Unplug the unit then disconnect the red and yellow wires from compressor terminals R S Using an ohmmeter check continuity between the points listed below 4 Compressor terminals C and S No continuity indi cates an open start winding The compressor must be replaced Normal start winding resistan...

Страница 6: ... not require a suction line filter drier 7 Evacuate the system with a good vacuum pump and accurate vacuum gauge Leave the pump on the system for at least an hour An alternate method of removing moisture and non condensibles from the system requires evacuation to 29 Hg vacuum Then break the vacuum with 35 to 50 PSIG refrigerant vapor charge Leave the vapor charge in the system for at least 5 minut...

Страница 7: ...Figure 2 Electrical Schematic of the DH 100V Dehumidifier 7 ...

Страница 8: ...35 MFD 370V 4017799 1 Compressor Run Capacitor for Tecumseh 25 MFD 440V 9 4021396 1 Condenser Coil 10 4021409 1 Cord Wire Harness 11 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip item 11 12 4021395 1 Evaporator Coil 13 4020955 1 Filter Drier 14 4021626 1 Hose Drain 56 ID x 8 15 4021469 1 Humidity Controller 16 4021495 1 Knob Humidity Controller 17 4020554 1 Switch SPDT fo...

Страница 9: ...nd American ALDES Ventilation Corporation s reasonable control Limitations and Exclusions If any American ALDES Dehumifier Dehumidifying Ventilator part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto All warranty periods shall be extended by the period of time if any that the unit is out of service while awaiting co...