K60 & KT60 STEAM BATH CONTROLS

FOR USE WITH AMEREC

AK STEAM GENERATORS

SAVE THIS MANUAL

FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE WARNINGS TO 
THE RIGHT AND ALL INSTRUCTIONS BEFORE USING YOUR STEAMBATH.

POST "WARNING" LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS. RE-
QUIRED POSTING ON DOOR OF STEAM ROOM OR ADJACENT TO DOOR FOR ALL 
COMMERCIAL INSTALLATIONS.

Thank you for purchasing your new AMEREC steam generator. If we can be of any assistance do not hesitate 
to call our Service Department at 1-800-363-0251 or 1-425-951-1120.

The K60 and KT60 controls provide automatic temperature control with AK steam generators. 

These controls allow the user to set steam bath time and to adjust the bath operating temperature.

Note: For a temperature controlled steam bath, the AK generator requires either a KT60 with built 

in temperature sensor or a K60 with separate temperature sensor. Another K60 may be added to 

allow two controls for a steam bath, such as one inside the room and one outside, but if a KT60 is 

installed it must be inside the steam room. A maximum of two controls may be installed.

1. Ensure that both the power circuit and water supply to the generator are ON.

2. To activate the steam, press the K60 (or KT60) control's On/Off switch. In 10 to 20 minutes 

    the room should be comfortable enough to begin taking a steam bath. The unit will turn off 

    automatically in 30 minutes. Note: other bath times and temperature may be set by the user.

3. Remove clothing and jewelry.

4. Enter the steam room and close the door to prevent steam from escaping.

5. Relax and enjoy the warm steam releasing tense muscles and refreshing the entire body. The

    average time spent taking a steam bath is approximately 10 minutes

6. Pressing the control's on/off switch while the steam generator is operating will shut it off. 

7. If your steam room has a shower, a pleasant experience can be achieved by taking a warm 

    shower while in the steam.  You will fi nd the contrast from water to steam quite invigorating. 

 SECTION 1: USING THE  K60/KT60 WITH An AMEREC GENERATOR

AK STEAM GENERATOR

K60 and KT60

WARNING

Electrical grounding is required

 on all Steam Generators.

All electrical supplies should be

disconnected when servicing a

Steam Generator.

All wiring must be installed by a 

licensed electrical contractor in 

accordance with local and

national codes.

All plumbing must be installed

by a licensed plumber in

accordance with all applicable

local and national codes.

Steamers are for indoor use only.

Steamers are not for

space-heating purposes.

Be certain that steam bath

enclosures are properly sealed

to avoid water damage from

escaping steam. It is

recommended that 100%

silicone caulk be used to seal

all pipes and fi ttings. Steam

must be prevented from

escaping into the wall cavity.

Never shut off the water to an 

appliance that is in use.

Electric Shock Hazard

High Voltage exists within this equipment. 

There are no user serviceable parts 

in this equipment. 

REDUCE THE RISK OF

1. Exit immediately if uncomfortable, dizzy or sleepy.  Staying too long in
    a heated area is capable of causing overheating.

REDUCE THE RISK OF

Use care when entering or exiting the steam room, floor may be slippery.

NOTE:  

For additional safety instructions, see owner's manual.

CAUTION!

 

Do not contact steam head. Stay at least 12" away
from hot steam escaping from the steam outlet.

OVERHEATING AND SCALDING

2. Supervise children at all times.

3. Check with a doctor before use if pregnant, diabetic, in poor health or
    under medical care.
4. Breathing heated air in conjunction with consumption of alcohol, drugs
   or medication is capable of causing unconsciousness.

SLIPPING AND FALL INJURY

WARNING

4110-79

05-21-07

113°

Содержание K60

Страница 1: ...team bath is approximately 10 minutes 6 Pressing the control s on off switch while the steam generator is operating will shut it off 7 If your steam room has a shower a pleasant experience can be achieved by taking a warm shower while in the steam You will find the contrast from water to steam quite invigorating SECTION 1 USING THE K60 KT60 WITH An AMEREC GENERATOR AK STEAM GENERATOR K60 and KT60 ...

Страница 2: ...t or possibly pregnant women should consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath f Persons using medication should consult a physician before using a steambath since some medi cation may induce drowsiness while other me...

Страница 3: ...60 and KT60 controls operate identically Bath Time The default bath time is 30 minutes adjustable from 5 to 60 minutes in 5 minute increments A jumper on the steamer board may be set for a bath time settable up to 24 hours max in 1 hour increments To check the time setting turn on the steam bath then press the TIME switch The set time will immediately be displayed Continue holding the switch for 5...

Страница 4: ...l either inside or outside the steam room The low volt age KT60 control must be mounted inside the steam room See step 2 above The control cable should already be roughed in to this location a With the decorative cover removed from the control switch assembly insert the two control mounting screws through the control housing you may need to punch through skinned holes and screw a few turns into th...

Страница 5: ...age Flushing Procedure The generator should be cool before starting 1 Use the control to start a bath Immediately go to the generator and open the manual drain open is with the handle in line with the drain pipe closed has the handle pointing straight out over the side of the pipe 2 Allow the tank to drain for a couple minutes then close the drain and allow the tank to fill for about 1 minute 3 Op...

Страница 6: ...emp 2 Contact Support Control ON Displays Steambath temperature over 132 F 55 C or Sensor faulty 1 If the bath is too hot turn off the circuit breaker and contact Support 2 Treat as E002 Control won t turn OFF Display is ON Control faulty Replace the control Contact Support Control ON Display ON Time Temp display properly Unit Won t steam Unit has not filled completely or Generator is faulty 1 Wai...

Отзывы: