  SECTION  6:  TROUBLE SHOOTING GUIDE

The troubleshooting guide is meant as a general aid only.  There are no user serviceable parts in the generator.  All repairs should be performed by a qualifi ed service 
person.  For additional assistance or the factory authorized service person nearest you call:  AMEREC's Service Department at 1-800-363-0251.

SYMPTOMS

PROBABLE CAUSES

ACTION TO BE TAKEN

Control won't turn ON
(Display is Off)

Improper or no power supplied

or

Control improperly connected

or

Control cable faulty

or

Control is faulty

1. a. Make sure circuit breaker for generator is on
    b. Use a voltmeter to check the voltage across the two fuses on 
        the Printed Circuit Assembly (PCA) in the generator.
    c. Check fuses; if a fuse is blown, replace. If the fuse blows again, 
        contact Support
2. Check that controls are installed per installation instructions.

3. Replace control cable. Contact support.

4. Replace control. Contact support.

Control OFF
(Unit still makes steam)

Generator faulty

Turn off the circuit breaker then contact Support.

Water runs out of steamhead

Generator Faulty

1. Turn off the breaker
2. Turn off the water supply
3. Contact Support.

Steam room too hot or cold

Temperature setting needs changing

1. See section 3: Setting Time and Temp
2. Contact Support

Control ON, Displays >>>°

Steambath temperature 

over 132°F (55°C)

or

Sensor faulty

1. If the bath is too hot, turn off the circuit breaker and contact Support
2. Treat as E002

Control won't turn OFF
(Display is ON)

Control faulty

Replace the control. Contact Support

Control ON (Display ON)
(Time & Temp display properly)
Unit Won't steam

Unit has not fi lled completely

or

Generator is faulty

1. Wait at least 10 minutes after turning on the control
2. Contact Support

Unable to adjust TIME or TEMP

Control faulty

or

Generator faulty

1. Replace control. Contact Support

2. Replace generator's PCA. Contact Support

Sudden increases in rate water 
sputters out of steam head

Contaminants in the water

supply causing foaming

Flush tank at least 3 time - refer to Section 5: Maintenance

Control displays E001

Steam room temperature error code

Open sensor or sensor cable. Contact Support

Control displays E002

Steam room temperature error code

Shorted sensor or sensor cable. Contact Support

Control displays E055

Steam room temperature error code

Room too hot. Contact Support

Control displays E007

Warm Start temperature error code

Open temperature sensor (Warm Start option). Contact Support

Control displays E008

Warm Start temperature error code

Shorted temperature sensor (Warm Start option). Contact Support

Control displays E044

Warm Start temperature error code

Possible burnt/failed heating element (Warm Start option). Contact Support

17683 128th Place NE, Bldg C
Woodinville, WA  98071   USA
Phone 1-425-951-1120
          

  

1-800-363-0251

email   [email protected]

Содержание K60

Страница 1: ...team bath is approximately 10 minutes 6 Pressing the control s on off switch while the steam generator is operating will shut it off 7 If your steam room has a shower a pleasant experience can be achieved by taking a warm shower while in the steam You will find the contrast from water to steam quite invigorating SECTION 1 USING THE K60 KT60 WITH An AMEREC GENERATOR AK STEAM GENERATOR K60 and KT60 ...

Страница 2: ...t or possibly pregnant women should consult a physician regarding correct exposure e Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath f Persons using medication should consult a physician before using a steambath since some medi cation may induce drowsiness while other me...

Страница 3: ...60 and KT60 controls operate identically Bath Time The default bath time is 30 minutes adjustable from 5 to 60 minutes in 5 minute increments A jumper on the steamer board may be set for a bath time settable up to 24 hours max in 1 hour increments To check the time setting turn on the steam bath then press the TIME switch The set time will immediately be displayed Continue holding the switch for 5...

Страница 4: ...l either inside or outside the steam room The low volt age KT60 control must be mounted inside the steam room See step 2 above The control cable should already be roughed in to this location a With the decorative cover removed from the control switch assembly insert the two control mounting screws through the control housing you may need to punch through skinned holes and screw a few turns into th...

Страница 5: ...age Flushing Procedure The generator should be cool before starting 1 Use the control to start a bath Immediately go to the generator and open the manual drain open is with the handle in line with the drain pipe closed has the handle pointing straight out over the side of the pipe 2 Allow the tank to drain for a couple minutes then close the drain and allow the tank to fill for about 1 minute 3 Op...

Страница 6: ...emp 2 Contact Support Control ON Displays Steambath temperature over 132 F 55 C or Sensor faulty 1 If the bath is too hot turn off the circuit breaker and contact Support 2 Treat as E002 Control won t turn OFF Display is ON Control faulty Replace the control Contact Support Control ON Display ON Time Temp display properly Unit Won t steam Unit has not filled completely or Generator is faulty 1 Wai...

Отзывы: