85
> diag
diag
Syntax:
diag
Description:
Tests whether UART, DRAM, Flash and EEPROM are working normally or not.
Arguments:
None.
Example:
SS2GD8I(diag)# diag
EEPROM Test
: OK
UART Test
: OK
DRAM Test
: OK
Flash Test
: OK
loopback
Syntax:
loopback
Description:
Tests internal/external loopback.
Arguments:
None.
Example:
SS2GD8I(diag)# loopback
Internal Loopback Test : OK
External Loopback Test : Port 1 2 3 4 5 6 7 8 Fail
ping
Syntax:
ping <ip>
Description:
Tests if the switch is able to ping a specific IP address or domain.
Arguments:
<ip>: IP address or domain name (e.g. 192.168.0.100 or www.yahoo.com)
Example:
SS2GD8I(diag)# ping 192.168.1.115
Gateway :
192.168.1.253
192.168.1.115 is alive.