3. CONNECTION 

Before  use  cylinder,  please  visually  check  all  units,  to  make  sure  there  are  no  damage  on 

cylinder,  port  threads,  coupler  and  hose.  No  oil  leaking  and  shortage  of  parts.  If  you  find  any 

problem  please  stop  using  your  equipment  and  contact  with  your  nearest  authorized  AME 

International Service Center or Sales office. 

 

Use a pump with a release valve or a 3-way valve and one hose to connect with lock nut cylinder. 

After connected all parts, please fully hand-tighten all couplers. If not, oil will be leaked when you 

operate the equipment.   

 

4. OPERATION 

WARNING: 

Tilt saddle (if available) must not exceed the maximum tilt angle of 5 ° (

   

 

 

                               

A                                    B                                C 

4.1 Operate hydraulic pump to advance (see A).

 

4.2 To hold the piston rod, clockwise rotate the Lock nut (see B) until reach to the top of cylinder 

(see C). 

4.3 To release the piston rod, Anticlockwise rotate the lock nut until reach to the top of piston rod   

4.4 After finish the work, release the pressure and fully return the piston rod, remove the hose 

and cover the coupler by rubber cap. 

 

IMPORTANT:

 Use less than the full stroke and use less full capacity if possible. Do 

not  allow  piston  rod  to  rotate  when  installing  adaptors  or  during  the  work,  rotating 

piston rod could damage the seals. 

 

5. MAINTENANCE 

  Please  always  use  clean  AME  International  oil  or  other  approved  hydraulic  oil.  Use  other 

unapproved oil or dirty oil will damage the cylinders. 